Manual

©2013 2GIG by Linear Corporation. All Rights Reserved. 1
2GIG Wireless Carbon Monoxide Alarm
INSTALL INSTRUCTIONS
TheWirelessCarbonMonoxideAlarm,partnumber2GIGCO3345isa3Vbattery
poweredwirelessdetectorintendedforusewithwirelessalarmsystems.The
detectorconsistsofanelectrochemicalcarbonmonoxidesensorassemblycoupled
toawirelesstransmitter.TheWirelessCarbonMonoxideAlarmcommunicateswith
theControlPanelandcan
sendalarm,tamperandbatteryconditionmessagesto
thesystem’sreceiver.To knowthemaximumnumberoftransmittersthatcanbe
supported,seethe2GIGSecuritySystemInstallGuide.
IMPORTANT: Thisdetectormustbete st edandmaintainedregularly
followingNFPA720requirements.
Thisdeviceisdesignedto
protectindividualsfromthe
acuteeffectsofcarbon
monoxideexposure.Itwillnot
fullysafeguardindividuals
withspecificmedical
conditions.Ifindoubtconsult
amedicalpractitioner.
WARNING: ThisCarbon
MonoxideAlarmis
intendedforusein
ordinaryindoor
residentialareas.Itisnot
designedtomeasure
compliancewith
OccupationalSafety&
HealthAdministration
(OSHA)commercialand
industrialstandards.
Box Contents
•WirelessCarbonMonoxideAlarmwithbase
•Packofscrewsandfixings
•Stickersasappropriate
•1CR123APanasonicbattery
TheWirelessCarbonMonoxideAlarmcontainsasounderwhichgenerat estheANSI
S3.41temporal4patterninanalarmcondition(fortemporal4 pattern,seethe
followingtable).Inalarm,amessageisalsosent
totheControlPanelandthe
detectorsIDisdisplayedonthescreen.Duringanalarmcondition,pressingthe
detectorshushbuttonwillsilencethesounderforfiveminutes.Themountingbase
installationissimplifiedbytheincorporationoffeaturescompatibleforboth
drywallfasteners(notsupplied)andothermethods.
Tri
coloredLED(green,yellow,red)andasounderonthedetectorprovidelocal
visualandaudibleindicationofthedetector’sstatusaslistedinthefollowingtable.
DuringinitialpoweruptheLEDblinksalternatelygreen,yellowthenred.Ittakes
about60secondsforthedetector’sCOsensortostabilize.
Afterpoweruphascompletedandthedetectorisfunctioningnormally,thegreen
LEDblinksonceevery12seconds.
Detector Trouble
Whenthesensorsupervisionisintroublecondition,theyellowLEDblinksonce
everysixsecondsandthereisachirpevery45seconds.After12hoursthepanel
willdisplayalossofsupervisionmessage.
Detector End-of-Life
Whenthedetectorhasreachedtheendofitslife,theyellowLEDblinksonceevery
23secondsandthereisachirpevery45seconds.After12hoursthepanelwill
displayalossofsupervisionmessage.ThisindicatesthattheCOsensorinsidethe
detectorhaspassedtheend
ofitslifeandthedetectormustbereplaced.The
detectorlifespanisfiveyearsfromthedateofmanufacture.
Low Battery Detection
TheWirelessCarbonMonoxideAlarmispoweredbyasingle3voltCR123A
PanasonicLithiumbattery.Thedetectorregularlychecksforalowbattery.Ifalow
batteryisdetected,thetransmittersendsalowbatterymessagetotheControl
Panel,whichdisplaysthedetector’sIDatlowbattery.Inaddition,
theyellowLEDof
thedetectorwillblinkevery12seconds.Thedetectorssounderwillchi rpevery45
seconds(yellowLEDcontinuestoblink)untilthebatteryisreplaced.Pressingthe
hushbuttonsilencesthechirpsfor12hours,ifnoothertroubleconditionsexist.
Replacethebatterywhenthe
chirpsbegin.Besuretoreplacethebatterywitha
freshone.
Constantexposurestohighorlowtemperaturesorhighhumiditymay
reducebatterylife!
Unauthorizedchangesormodificationscouldvoidtheusersauthority
tooperatetheequipment.
Inserting and Replacing Batteries
1 Removethedetectorfr omitsmountingbasebytwistingthedetector
counterclockwise.Removeanddisposeofthebatteryaccordingtolocal
regulations.
2 Toensureproperpowerdownsequence,waitaminimumof20secondsbefore
installingnewbattery.
3 Installanew3voltCR123APanasonicLithiumbattery(availablefromyour
Panasonicdealer)inthebatterycompartment.Followthepolaritydiagram
insidethecompartment!Ifthebatteryisincorrectlyinserted,removegently
withanonconductivetoolandcorrectlyreinsert.
4 Reinstallontothemountingbasebyturningthedetectorclockwise.
5 AfterthepowerupsequencethegreenLEDshouldblinkaboutonceevery12
secondstoindicatenormaloperation.Ifthebatteryisnotinstalledcorrectly,
thedetectorwillnotoperateandthebatterymaybedamaged.Ifthedetector
doesnotpowerup,checkforafullychargedbattery .
Status LEDs Sounder
(doesnotpulse
thesounderand
LEDconcurrently)
RadioSignaling 2GIGControl
PanelResponse
Normal Greenflash
every12
seconds
Off Normal(None) Normal(None)
Alarm/Test Redflashevery
12seconds
ANSIS3.41
temporal4
(pressbuttonto
hushfor5
minutes)
Alarm Onscreenand
audibleAlarm
(usercodeto
silence)
Detector
Trouble
Yellowflash
every6
seconds
One100ms
chirpevery45
seconds
Fault OnscreenAlert
shown(after12
hours)“Device
name‐‐”Lossof
Supervision
LowBattery Yellowflash
every12
seconds
One100ms
chirpevery45
seconds(press
buttontohush
for12hours)
LowBattery OnscreenAlert
shown“Device
name‐‐
BatteryLow
DetectorEnd
ofLife
Yellowflash
every23
seconds
One100ms
chirpevery45
seconds
None Normal(None)
PowerUp Green,Yellow,
Redflash
sequence
every12
seconds
One100ms
chirpatendof
powerup
sequence
None Normal(None)
Tamper Green,Yellow,
Redflash
sequence
every12
seconds
Off Tamper OnscreenAlert
shown
“Devicename‐‐
Tamper