User guide

GLASS BREAK DETECTOR
INSTALL INSTRUCTIONS
TheGlassBreakDetectorisafullysuper vised,tamperprotected,ceiling
orwallmountedunitwith15feetmaximumdetectionrange,
360°maximumhorizontalsensingangle,anddualstageglassbreak
detection.
Box Contents
•Mountingbase
•Sensor
•2Lithiumbatteries
•3Phillipsheadscrews
•3Wallanchors(plastic)
Programming
Thefollowingstepsdescribegeneralguidelinesforprogramming
(learning)theGlassBreakDetectorintotheContr olPanel.Scrollbetween
oponsusingthe←and→arrows.Movetothepreviousornextprompt
bypressingthe↑and↓arrows.
1 SelectRFsensor#(01to48).AssigntheGlassBreakDetectortoa
newzone.
2 SelectRFsensortype:
(03)glassbreak
3 SelectRFsensorequipmentcode.Enter5853fortheGlassBreak
Detector.
4 SelectRFequipmenttype.
(1)co
ntact
5 EnterRFsensorserialnumber(7digits).
ManualEntry:Typeinthelast7digitsoftheTXIDthatisfound
outsideoftheboxoronthebackofthedevice.
AutoEntry:WiththepanelinLearninmode,(pressShiftthenLearn)
pressthetamperswitch.ThecorrectTXIDshouldap
pear.Acceptthe
correctTXIDbypressingok.
Remembertopr
essthe↓arrowtocontinuegoingthroughthe
systemconfigurationprompts.
6 SelectRFsensorequipmentage(0to1).
(0)new(
productisnew)
(1)ex
isting(productalreadyexists)
7 SelectRFsensorloopnumber(1to3).
8 SelectRFSensordialerdelay(0to1)
(0)disable
d
9 ConstructRFsensorvoicedescriptor.PressInsert thenpressany
numberbetween002and255toaddaword.Repeatthisforeach
word.Forexample,ifyouwanttonamethisGlassBreakDetectoras
the“masterbedroom,pressInsertthenpress140formaster.Press
Insertthenpress024fo
rbedroom.
10 SelectRFsensorreports(0to1).
(0)disable
d(GlassBreakDetectordoesNOTreporttocentralstation)
(1)ena
bled(GlassBreakDetectorreportstocentralstation)
11 SelectRFsensorsupervised(0to1)
(0)disable
d(detectordoesnotreportlossofsupervision/lowbattery)
(1)ena
bled(detectorreportslossofsupervision/lowbattery)
12 SelectRFsensorchime(0to13).
(0)disable
d(panelwillNOTchimewhenGlassBreakDetectoris
activated)
(113
)enabled(selectsavoiceandchimetosoundonthepanelwhen
theGlassBreakDetectorisactivated)
13 Toprogramanothersensorclicknext.
14 Toexitprogramming,clickskipthenendandexit.Uponexit,the
paneltak esseveralsecondstoreboot.
Testing
Walk Test
1 Pushthetestbuttonfor2seconds
andthenreleaseit.TheredLED
appearswhile thebuttonispressed.
2 ThegreenLEDwillblinkonceto
indicatethattheunitisinautotest
modefor90seconds.
3 Activateaglassbreaksimulatorinthe
areaofthewindoworwindowsthat
youareattemptingtoprotectwith
theglassbreakdetector.TheGlassBreakDetectorshouldfirst
acknowledgethedetectionofathudsoundbyilluminatingthegreen
LEDandthenilluminatetheredLEDwhentheunitde
tectsthecrash
portionoftheglassbreakingsound.
RF Test
•Pushandholdthetestbuttonfor5secondsandthenreleaseit.The
redLEDappearswhilethebuttonispressed.ThegreenLEDwillblink
twicetoindicatethattheunitisinRFtestmodefor90seconds.
NOTE: Performasystemtest(pertheUserGuide)atleastoncea
year.
Glass Type/Thickness
Minimumsizeforallglasstypesis11”x11”(28cmx28cm)square;glass
mustbeframedinthewalloftheroomormountedinabarrierof36”
(.9m).
Sealedinsulangglasstypesareprotectedonlyifbothplatesofglass
arebroken.
TIP: Whenwallmounted,theGlassBreakDetectorisdesignedto
providecoverageontheoppositeoradjacentwindowsandnot
onwindowsonthesamewallastheGlassBreakDetector.
Installation
1 Holdthe2GIGGB1345GlassBreak
Detectorunitupsidedownandtwistthe
basecounterclockwisetoremoveit.
2 Installrecommendedbatteriesmaking
suretoobservethecorrectpolarity.
3 Wait5secondsforthepowerupdelay.
4 Entertheprogrammingmodefora
wirelessdeviceonthe2GIGalarm
controlpanel.
5 LearntheGlassBreakDetectorintothe
ControlPanelbypressingandholdingthetamperswitchfor2
seconds.
Type Minimum to Maximum Thickness
Plate 1/8in.to1/4in.(3.2mmto6.4mm)
Tempered 1/8in.to1/4in.(3.2mmto6.4mm)
SealedInsulang† 1/8in.to1/4in.(3.2mmto6.4mm)
FCCID:WDQGB1345
IndustryCanadaID:7794AGB1345