Dear customer, Let us congratulate you on having purchased the EasyGate UMTS Data system. This new product has been developed and manufactured to provide the maximum utility value, quality and reliability. We hope you will be fully satisfied with this UMTS/GSM gateway for a long time. Therefore, use your EasyGate UMTS Data for purposes it has been designed and manufactured for, in accordance herewith. The manufacturer reserves the right to modify the product in order to improve its qualities.
User Manual Versions Version Amendments to Earlier Versions 1.00 • The User Manual applies to EasyGate UMTS Data FW Version 2.20K Upgrade The manufacturer continuously meets customer requirements by improving the firmware. For the latest EasyGate UMTS Data processor firmware, programming tool and User Manual see www.2n.cz. For a detailed description of the EasyGate UMTS Data firmware upgrade refer to the section devoted to the PC programming tool.
Packing List An EasyGate UMTS Data delivery contains the following items: Item EasyGate UMTS Data Number of Pieces 1 pc Antenna for direct connection 1 pc 1) Magnetic Antenna with coax cable 1 pc 1) Supply adapter 1 pc Telephone cable 1 pc PC-connection USB cable 1 pc PC-connection serial cable ( only for gateway upgrade and programming) 1 pc Dowels 2 pcs Bolts 2 pc CD-ROM with User Manual and software 1 pc 2) Quick Installation Guide + mounting pattern 1 pc Warranty certificate 1 pc
CONTENTS 1. EASYGATE UMTS DATA PURPOSE .................................................................................. 5 1.1. 1.2. 2. INSTALLATION .................................................................................................................... 6 2.1. 2.2. 2.3. 2.4. 2.5. 2.6. 2.7. 3. USB INTERFACE DRIVERS INSTALATION ..................................................................................... 17 CONNECTION SETTINGS AND START................................................
1. EasyGate UMTS Data purpose 1.1. Basic Functions • • • • The primary purpose of EasyGate UMTS Data is to transmit voice between a UMTS or GSM network and an attached FXO-interface terminal (PBX, telephone, answering machine, etc.). You can establish fast internet HSDPA connection or GPRS connection. You can send an SMS to a pre-programmed number using the SMS sending input. EasyGate UMTS Data can’t establish data/fax connections! 1.2.
2. Installation 2.1. Proper Location • • • • • • • • EasyGate UMTS Data is designed for vertical mounting on suspension holes (use the mounting pattern). This position is the best for signal reception because a vertical antenna is used. EasyGate UMTS Data can be operated in the horizontal position too where the UMTS signal is good. Install EasyGate UMTS Data with respect to the UMTS signal strength.
2.2. External Antenna Connection Screw the antenna enclosed into the SMA antenna connector. Tighten the antenna connector gently with your hand - never use wrenches! The antenna enclosed has a sufficient gain for trouble-free operation in normal conditions. If the UMTS signal is poor or you want to place your antenna separately from EasyGate UMTS Data, you can use an antenna with an SMA-connector terminated cable. The antenna should be mounted vertically.
2.4. Connector description 5 1 1 1 2 22 3 3 3 4 1 USB interface 2 Telephone line RJ 12, 6/2 3 Power supply connector DC Jack 2,1mm 4 RS232C serial line D-Sub 9 pins 44 2.5. Telephone Line Connection 2.5.1. PBX Connection Connect EasyGate UMTS Data to a free CO line of your PBX. Configure your PBX in such a manner that UMTS/GSM outgoing calls are routed to EasyGate UMTS Data. EasyGate UMTS Data is equipped with the FSK-based CLIP function.
3. EasyGate UMTS Data Status Indication 3.1. Indication LEDs Name Meaning Power supply • Light = EasyGate UMTS Data is powered. • Flashes once in 2s = HW error, contact the manufacturer. UMTS/GSM network • Light = registered to UMTS/GSM • Flashes once in 1s = not registered, USIM card inserted • Flashes once in 3s = not registered, USIM card not inserted • Flashes 4 times quickly = enter your PIN • Flashes 8 times quickly = enter your PUK • Flashes quickly continuously = all functions are blocked.
Dialing end signaling: • Dialing reception has been terminated. Connection is being established. PIN tone: • Enter the PIN code. • This tone is transmitted upon power up if the PIN has to be entered manually. PUK tone: • Enter the PUK code. • This tone is transmitted upon repeated wrong PIN entering attempts. USIM card is blocked. 3.2.2. Programming Mode Tones Tones confirming/refusing the values entered are transmitted during telephone line based programming. Each tone has a different melody.
4. USIM Card PIN protection If a USIM card is PIN-protected and the PIN is not programmed in EasyGate UMTS Data, network LED indicates the state and the PIN tone is transmitted on telephone line. 4.1. PIN Entering by PCManager Like other parameters, the PIN code can be entered using a PC programming tool. The PIN will be entered automatically upon next EasyGate UMTS Data power up. 4.2. PIN Entering via Telephone Line To enter the PIN via a telephone line using the DTMF: 1.
5. Voice function Outgoing and incoming call establishing procedures for an analog telephone are described for illustration. The procedures are the same for the EasyGate UMTS DataPBX connection, just remember to program call routing to EasyGate UMTS Data properly. Check EasyGate UMTS Data’s function by connecting a telephone before.
5.3. Automatic Call ("Baby Call") If the Baby Call function is enabled, a pre-programmed period of time is counted down after off-hook. If you do not start dialing within this timeout, EasyGate UMTS Data signals dialing end and starts establishing a call to the pre-programmed number automatically – from now on EasyGate UMTS Data behaves as if a standard outgoing call had been established. Any dialing during the Baby Call timeout cancels this function and a standard outgoing call can be made. 5.4.
5.6. Call forwarding For forwarding activation you must specify the calls will be forwarded to. You may specify , if you want to forward specified call type only. You may specify in seconds for forwarding if no answer too. Description of field codes: Voice: Data: Fax: 5.6.1. Call forwarding unconditional If activated, incoming calls will be always forwarded to the configured telephone number.
Activation for all call types and specified delay time: Activation for selected call type and specified delay time: Deactivation: Status check: 5.6.4. Call forwarding if not accessible If activated, incoming calls will be forwarded to the configured telephone number if your EasyGate is not accessible in the GSM network.
To terminate all held calls, or reject waiting call dial: To terminating active call and accept the held or waiting call dial: To place the active call on hold and accept the held or waiting call (switching between two calls) dial: To place all held calls to active calls and set up conference call dial: To connect the two calls (active and held) and disconnect the EasyGate from both calls dial: 16
6. USB interface You can use HSDPA or GPRS internet access or CSD connection when connecting Your EasyGate UMTS DATA with PC via USB interface. 6.1. USB interface drivers instalation It is needed to install USB modem drivers for properly function of USB interface. When the gateway is connected with PC for the first time the Windows operating system will find automatically the new hardware. Choose the Find drivers in PC option and set the drivers’ directory path.
7.1. Programming Install the EasyGate UMTS Data PCManager software available on the included CDROM into your PC. The program is designed for EasyGate UMTS Data parameter programming. It can read configuration data from the memory and store them in EasyGate UMTS Data. Moreover, all parameters can be saved in your PC file for backup or saving into another EasyGate UMTS Data system.
8. EasyGate UMTS Data Parameter Programming All EasyGate UMTS Data parameters have such default values that meet most users’ demands and need not be changed. To change EasyGate UMTS Data parameters in spite of that, you can either: • Use a PC with the PCManager installed. All functions supported by EasyGate UMTS Data can be set using the PC. • Or use the DTMF programming on a telephone line. Not all functions can be set in this way. 8.1. Telephone Line based Programming 1.
8.2. PC based Programming For programming, connect EasyGate UMTS Data to a PC with a serial cable and make sure that the EasyGate UMTS Data PCManager is installed. Programming is intuitive and easy. All steps are accompanied with texts hints above all items you point at with the mouse. EasyGate UMTS Data data uploading and storing, including firmware upgrade, are executed in a special mode, in which EasyGate UMTS Data waits for about 3s after power up (all LEDs are on).
7. Save data into EasyGate UMTS Data – if EasyGate UMTS Data is not in its special programming mode, you are invited to switch EasyGate UMTS Data off and on again. 8.2.2. Further Data Handling Options In addition to the EasyGate UMTS Data memory, settings can be saved in a PC file and reloaded into the PCManager. This is recommended for backing up of current configurations or saving the same configuration in another EasyGate UMTS Data unit.
UMTS Date is made in version B only. After connecting EasyGate UMTS Data to PC the program checks the version settings. If the version is set wrong, the program asks You to change the settings.
8.3. Parameter Tables All programmable parameters are listed in this section. Each parameter is accompanied with the unit used, function number (if available) for programming via a telephone line, description of EasyGate UMTS Data's behavior, setting options, setting step and default (initialization) value. 8.3.1. Telephone Line Parameters 8.3.1.1 Dialing parameters Type of dialing Function No.: Select the dialing type to be received by EasyGate from the PBX or telephone set.
None Call end Call start Call start and end -EasyGate doesn't send tariff pulse as signaling of call start/end. -EasyGate sends tariff pulse when call ends. -EasyGate sends tariff pulse when call starts. -EasyGate sends tariff pulse when call starts and ends too. Default setting: None Tariff pulse frequency Function No.: Tariff pulse frequency setting. Setting options: 16 kHz -EasyGate transmits 16 kHz tariff pulses 12 kHz -EasyGate transmits 12 kHz tariff pulses Default setting: 16 kHz - 8.3.1.
Busy tone - cadence Function No.: Busy tone cadence setting. Setting options: 330/330 ms -cadence 330 ms tone, 330 ms pause 200/200 ms -cadence 200 ms tone, 200 ms pause 250/250 ms -cadence 250 ms tone, 250 ms pause 375/375 ms -cadence 375 ms tone, 375 ms pause 500/500 ms -cadence 500 ms tone, 500 ms pause Default setting: 330/330 ms - Tone after disconnection Function No.: If the remote subscriber hangs up first, the EasyGate subscriber can hear the tone selected here.
Ringing signal – cadence DATA/Fax Function No.: This setting doesn’t influence EasyGate UMTS Data. EasyGate UMTS Data doesn’t support Data/Fax calls. CLIP Function No.: 19 Set this item to enable/disable identification of a telephone line calling from a GSM network. The function can be enabled if you have a device on your telephone line that is capable of receiving FSK according to ETSI standards. Setting options: Disable -EasyGate does not transmit the CLI.
8.3.2. FXS routing parameters All parameters related to the number dialed for an outgoing call are arranged in this table. According to the prefix you can: • Bar the number to be dialed - the calling subscriber hears the busy tone; • Accelerate connection establishing by knowing the number length for the given prefix; • Accelerate connection establishing by allowing to terminate dialing with a #; • Modify the number to be dialed by removing and/or adding digits. • Set tariff metering for the given prefix.
Routing table enable Function No.: 20 Enable the use of the routing table with this parameter. Disabling this parameter you put the table out of use. Setting options: YES/NO Default setting: NO Prefix Function No.: A prefix identifying the call type (GSM, trunk call, free call, etc.). "Other numbers" line is used for calls with prefixes that are not included in the table. Setting options: 0-14 characters (0-9,*,#) Default setting: blank Call enable Function No.
Extra tariff Function No.: Pseudo tariff metering setting (tariff is based on call duration). The Extra tariff parameter defines transmitting of fixed quantity of tariff pulses after call start. This parameter sets minimal call cost. Setting options: 0-255 Setting step: 1 Default setting: 0 Tariff [s] Function No.: Pseudo tariff metering setting (tariff is based on call duration). The Tariff parameter sets the call cost according to call duration. Set how often in seconds do you want to transmit pulses.
Setting options: -Disable -The GSM module logs out of a foreign network and attempts to register again in within 5 minutes. -Enable -EasyGate works in any GSM network. Default setting: Disable Incoming calls enable Function No.: With this parameter you can reject all incoming calls. Setting options: Enable - Incoming calls ring on the telephone line. Disable - Incoming calls are rejected. Default setting: Enable 43 Call Handover workaround Function No.
Credit value position in received SMS Function No.: If there are more numbers except credit value in text answer (e.g. date, time and so on) EasyGate seeks the number corresponding with credit value from given position in text. The seek algorithm skips every non-number character. If credit value is the first number in text you can leave setting 0. If there are other numbers before credit value, set parameter to text position, from which the algorithm will seek.
8.3.6. Service Parameters Hardware version Function No.: EasyGate UMTS Data hardware version - for information only (cannot be modified). Must be used for communication with the manufacturer. Firmware version Function No.: EasyGate UMTS Data firmware version - EasyGate UMTS Data central processor program version. The manufacturer can issue upgrades to extend functions. To load new firmware into EasyGate UMTS Data use the Upgrade function. Keep communicating with the manufacturer. Serial number Function No.
Initialization of GMS/UMTS & USIM Function No.: 94 Initialization of all parameters related to the UMTS/GSM network and USIM card (except for the PIN code). SMS input initialization Function No.: 93 Initialization of all parameters for SMS sending upon SMS input activation. Global initialization Function No.: 99 Initialization of all EasyGate UMTS Data parameters including the PIN and service password.
8.3.8. Security Parameters PIN - value Function No.: 40 Fill in the PIN value for automatic PIN entering upon EasyGate UMTS Data power up. It is applied only if the USIM card is PIN secured. If the given PIN fails to match the USIM, it is deleted automatically. If entered via a telephone line upon EasyGate UMTS Data start, the PIN is stored automatically. Setting options: 0, 4-8 characters (0-9) Upon full initialization: blank Service password Function No.
9. Troubleshooting No LED is on after power up • Check the power supply. All LEDs are on. No call is currently in progress. • EasyGate UMTS Data is in the special PCManager-based programming mode - exit the PCManager to reset EasyGate UMTS Data. • Try to switch EasyGate UMTS Data off and on, the LEDs should go off in 3s and signal the status of EasyGate UMTS Data. EasyGate UMTS Data does not register to UMTS/GSM • Check the USIM card. • Check the PIN. • Check the antenna connection.
10.
Technical Parameters – UMTS EasyGate: UMTS/GSM: UMTS module, bandwidth Transmission power Receiver sensitivity Audio DATA Antenna USIM card UC 864-E UMTS 2100, EGSM 850/900, GSM 1800/1900 MHz UC 864-G UMTS 850/1900/2100, EGSM 850/900, GSM 1800/1900 MHz 0.25W UMTS 850/1900/2100 MHz 2 W EGSM 850 / 900 MHz 1W GSM 1800 / 1900 MHz -108.