Maintenance
Fault Diagnostics
Front Panel Indicators
The five LED indicators on the front panel are used to diagnose server fault conditions. The
meaning of each indicator is noted in the following table. During normal operation, all five
LEDs will be on.
GENLOCK OFF indicates that the Genlock
setting in the System menu is
“Internal”
FLASHING indicates that Genlock is
selected in the System menu, but
there is no signal, or an invalid signal,
at the GENLOCK input connector.
Check the Genlock setting in the On-
Screen System menu.
Check the Genlock cable connections
or signal.
POWER FLASHING indicates that there is a
fault in the system power supply.
Shut down the server and contact 360
Systems Customer Support for further
hardware diagnosis.
FANS FLASHING indicates that an internal
chassis or CPU fan is running slow or
stopped.
Check the chassis fan operation.
Replace if necessary. Do not run the
server without a working fan.
DRIVES FLASHING indicates that there is a
fault in the system RAID array.
Check the RAID array status using
the utility under
Start >Raid Status.
SYSTEM FLASHING indicates that the CPU or
other temperature or voltage reading
is not within manufacturer’s
specification.
Shut down the server and contact 360
Systems Customer Support for further
hardware diagnosis.
Repairs should be performed only by
qualified electronics technicians.