User Guide

(English)
4
3M™ Accessories and Parts
Number ****AAD Description
504 07065 Respirator Cleaning Wipes
601 Quantitative Fit Test Adapter
6878 07141 Spectacle Kit
6885 07142 Lens Cover
6886 Tinted Lens Cover
7883 Neck Strap Assembly
**** AAD part numbers are catalog numbers only. NIOSH approved as PSD part numbers
CAUTION
Failure to properly dispose of spent cartridges, lters, or respirators contaminated by hazardous materials can result in personal exposures as well
as environmental harm. Handling, transportation and disposal of spent cartridges, lters, or respirators must comply with all applicable federal,
state, provincial, and local laws and regulations.
3M™ Cartridges 6000 Series
Number ****AAD Description NIOSH Approval for respiratory protection against the following
contaminants up to ten times the permissible exposure limit
(PEL) when qualitatively t tested, up to fty times the PEL when
quantitatively t tested, and up to 1000 times the PEL in powered
air-purifying or supplied air mode
6001 07046 Organic Vapor Certain organic vapors
6001i Organic Vapor with Service Life Indicator Certain organic vapors
6002 Acid Gas Chlorine, hydrogen chloride, and sulfur dioxide or chlorine dioxide or
hydrogen sulde
6003 07047 Organic Vapor/Acid Gas Certain organic vapors, chlorine, hydrogen chloride, and sulfur dioxide or
hydrogen sulde or hydrogen uoride
6004 Ammonia/Methylamine Ammonia and methylamine
6005 Formaldehyde/Organic vapor Formaldehyde and certain organic vapors
6006 Multi-Gas/Vapor Certain organic vapors, chlorine, hydrogen chloride, chlorine dioxide,
sulfur dioxide, hydrogen sulde, ammonia/methylamine, formaldehyde
or hydrogen uoride
6009S Mercury Vapor/Sulfur Dioxide/Chlorine Gas Mercury vapor, sulfur dioxide or chlorine gas
60921 Organic Vapor/P100 Certain organic vapors and particulates
60921i Organic Vapor with Service Life Indicator/P100 Certain organic vapors and particulates
60922 Acid Gas/P100 Chlorine, hydrogen chloride, and sulfur dioxide or chlorine dioxide or
hydrogen sulde and particulates
60923 Organic Vapor/Acid Gas/P100 Certain organic vapors, chlorine, hydrogen chloride, and sulfur dioxide or
hydrogen sulde or hydrogen uoride and particulates
60924 Ammonia/Methylamine/P100 Ammonia and methylamine and particulates
60925 Formaldehyde/Organic Vapor/P100 Formaldehyde and certain organic vapors and particulates
60926 Multi-Gas/Vapor/P100 Certain organic vapors, chlorine, hydrogen chloride, chlorine dioxide,
sulfur dioxide, hydrogen sulde, ammonia/methylamine, formaldehyde
or hydrogen uoride and particulates
60928 Organic Vapor/Acid Gas/P100 Certain organic vapors, chlorine, hydrogen chloride, and sulfur dioxide or
hydrogen sulde or hydrogen uoride and particulates
1
60929S Mercury Vapor/Sulfur Dioxide/Chlorine Gas/P100 Mercury vapor, sulfur dioxide or chlorine gas and particulates
**** AAD part numbers are catalog numbers only. NIOSH approved as PSD part numbers.
1
3M recommended for use against methylbromide or radioiodine up to 5 ppm with daily cartridge replacement. NOTE: Not NIOSH approved for use
against methylbromide or radioiodine.
Service Life of Chemical Cartridges and Particulate Filters
3M™ Chemical Cartridges 6000 Series must be used before the expiration date on cartridge packaging. The useful service life of these cartridges
will depend upon activity of wearer (breathing rate), specic type, volatility and concentration of contaminants and environmental conditions such
as humidity, pressure, and temperature. Cartridges must be replaced in accordance with an end of service life indicator (ESLI), established change
schedule, regulations or earlier if smell, taste or irritation from contaminants is detected.