User Guide
(English)
5
Particulate lters must be replaced if they become damaged, soiled or if increased breathing resistance occurs. N-series lters should not be used in
environments containing oils. R-series lters may be limited to 8 hours of continuous or intermittent use if oil aerosols are present. In environments
containing only oil aerosols, P-series lters should be replaced after 40 hours of use or 30 days, whichever is rst.
3M™ Filters, Adapters, Retainers
NOTE: Only 3M™ Filters approved under NIOSH 42 CFR 84 are to be used with the 3M™ Full Facepiece 6000 Series.
Number ****AAD Description
501 07054 Filter Retainer for Filters 5N11 and 5P71
502 Filter Adapter for Filters 2000 Series and 7093/7093C
603 Filter Adapter for Filters 5N11, 5P71 with Filter Retainer 501
2071 Particulate Filter, P95
2076HF Particulate Filter, P95, hydrogen uoride, with nuisance level acid gas relief
1
2078 Particulate Filter, P95, 3M recommended ozone protection
2
, with nuisance level organic vapor/acid gas relief
1
2091 07000 Particulate Filter, P100
2291 Advanced Particulate Filter, P100
2096 Particulate Filter, P100, with nuisance level acid gas relief
1
2296 Advanced Particulate Filter, P100, with nuisance level acid gas relief
1
2097 07184 Particulate Filter, P100, 3M recommended for ozone protection
2
, with nuisance level organic vapor relief
1
2297 Advanced Particulate Filter, P100, 3M recommended for ozone protection
2
, with nuisance level organic vapor relief
1
5N11 Particulate Filter, N95
5P71 07194 Particulate Filter, P95
7093 Particulate Filter, P100
7093C 37173 Particulate Filter, P100, hydrogen uoride, with nuisance level organic vapor/acid gas relief
1
**** AAD part numbers are catalog numbers only. NIOSH approved as PSD part numbers.
1
3M recommended for relief against nuisance levels of acid gas and/or organic vapors. Nuisance level refers to concentrations not exceeding OSHA
PEL or applicable exposure limits, whichever is lower. Do not use for respiratory protection against acid gas/organic vapors.
2
3M recommended for ozone protection up to 10 times the OSHA PEL or applicable government occupational exposure limits, whichever is lower.
NOTE: Not NIOSH approved for use against ozone.
In Brazil, the 3M™ Filter 5935BR can be used with the Filter Adaptor 603 and the Filter Retainer 501 on the 3M™ Half Facepiece 6000 Series.
ASSEMBLY INSTRUCTIONS
NOTE: Make certain 3M™ Inhalation Port Gaskets 6895 are in place on the facepiece bayonet connectors before installing lters, cartridges or
breathing tubes.
3M™ Cartridge Assembly 6000 Series
1. Align the cartridge notch with the small solid bayonet lug on facepiece and push together.
2. Turn cartridge clockwise to stop (1/4 turn).
3. Repeat with second cartridge (Fig. 1).
6864_w6000cart2_turn.eps
4/12/04 K&K
Fig. 1
3M™ Filters 2000 Series and Filter Assembly 7093/7093C
1. Align opening of lter with lter attachment on facepiece.
2. Turn lter clockwise until it is rmly seated and cannot be further turned.
3. Repeat for second lter (Fig. 2).