Particulate lters must be replaced if they become damaged, soiled or if increased breathing resistance occurs. N-series lters should not be used in
environments containing oils. R-series lters may be limited to 8 hours of continuous or intermittent use if oil aerosols are present. In environments
containing only oil aerosols, P-series lters should be replaced after 40 hours of use or 30 days, whichever is rst.
3M™ Filters, Adapters, Retainers
NOTE: Only 3M™ Filters approved under NIOSH 42 CFR 84 are to be used with the 3M™ Full Facepiece 6000 Series.
Number ****AAD Description
501 07054 Filter Retainer for Filters 5N11 and 5P71
502 Filter Adapter for Filters 2000 Series and 7093/7093C
603 Filter Adapter for Filters 5N11, 5P71 with Filter Retainer 501
2071 Particulate Filter, P95
2076HF Particulate Filter, P95, hydrogen uoride, with nuisance level acid gas relief
1
2078 Particulate Filter, P95, 3M recommended ozone protection
2
, with nuisance level organic vapor/acid gas relief
1
2091 07000 Particulate Filter, P100
2291 Advanced Particulate Filter, P100
2096 Particulate Filter, P100, with nuisance level acid gas relief
1
2296 Advanced Particulate Filter, P100, with nuisance level acid gas relief
1
2097 07184 Particulate Filter, P100, 3M recommended for ozone protection
2
, with nuisance level organic vapor relief
1
2297 Advanced Particulate Filter, P100, 3M recommended for ozone protection
2
, with nuisance level organic vapor relief
1
5N11 Particulate Filter, N95
5P71 07194 Particulate Filter, P95
7093 Particulate Filter, P100
7093C 37173 Particulate Filter, P100, hydrogen uoride, with nuisance level organic vapor/acid gas relief
1
**** AAD part numbers are catalog numbers only. NIOSH approved as PSD part numbers.
1
3M recommended for relief against nuisance levels of acid gas and/or organic vapors. Nuisance level refers to concentrations not exceeding OSHA
PEL or applicable exposure limits, whichever is lower. Do not use for respiratory protection against acid gas/organic vapors.
2
3M recommended for ozone protection up to 10 times the OSHA PEL or applicable government occupational exposure limits, whichever is lower.
NOTE: Not NIOSH approved for use against ozone.
In Brazil, the 3M™ Filter 5935BR can be used with the Filter Adaptor 603 and the Filter Retainer 501 on the 3M™ Half Facepiece 6000 Series.
ASSEMBLY INSTRUCTIONS
NOTE: Make certain 3M™ Inhalation Port Gaskets 6895 are in place on the facepiece bayonet connectors before installing lters, cartridges or
breathing tubes.
3M™ Cartridge Assembly 6000 Series
1. Align the cartridge notch with the small solid bayonet lug on facepiece and push together.
2. Turn cartridge clockwise to stop (1/4 turn).
3. Repeat with second cartridge (Fig. 1).
6864_w6000cart2_turn.eps
4/12/04 K&K
Fig. 1
3M™ Filters 2000 Series and Filter Assembly 7093/7093C
1. Align opening of lter with lter attachment on facepiece.
2. Turn lter clockwise until it is rmly seated and cannot be further turned.