User Guide

(English)
6
Fig. 2
Filter Assembly (for 3M™ Filters 5N11 and 5P71)
1. Place lter into 3M™ Retainer 501 *(07054) so printed side of lter faces the cartridge.
2. Press cartridge into lter retainer. It should snap securely into lter retainer. When correctly installed, lter should completely cover face of
cartridge (Fig. 3).
3. To replace lter, remove retainer by lifting on TAB.
Fig. 3
In Brazil, the 3M™ Filter 5935BR is assembled following the same procedures as the 5N11 and 5P71.
3M™ Filter Adapter 502 Assembly and Filter Attachment
1. Align adapter over cartridge. Engage front snap by squeezing front of cartridge and adapter together, placing thumbs of both hands over top of
adapter and ngers along bottom sides of cartridge (Fig. 4).
2 Engage back snap by squeezing back side of cartridge and adapter together using the same hand positions. An audible click should be heard as
each snap is engaged (Fig. 5).
3. Place lter onto the lter holder so that lter comes into even contact with gasket. Twist clockwise a quarter turn until it is rmly seated and lter
cannot be turned further. Repeat for second lter.
NOTE: The 3M™ Filter Adapter 502, once installed on a 3M™ Cartridge 6000 Series, is not to be removed or reused. Removal or reuse may
result in leakage, overexposure, sickness or death.
Fig. 4 Fig. 5
3M™ Filters 2000 Series and 7093/7093C with 3M™ Filter Adapter 502
Place lter onto the lter holder so that lter comes into even contact with gasket. Twist clockwise one quarter turn until it is rmly seated and lter
cannot be turned further. Repeat for second lter.
NOTE: The 3M™ Filter Adapter 502, once installed on a 3M™ Cartridge 6000 Series, is not to be removed or reused. Removal or reuse may
result in leakage, overexposure, sickness or death.