Precision Health Scale UC-324NFC Instruction Manual 1WMPD4002355B
Contents Before Use Precautions ........................................................................................................ 1 Scale Components............................................................................................. 2 Display Symbols ................................................................................................ 3 Automatic Power-Off Function ...........................................................................
Scale Components SET Switch Communication Area Front Battery Compartment Handle Scale Leg Display Ready/Stable Symbol Back Battery Indicator Unit Accessories Instruction manual Batteries 2 Add-on feet
Display Symbols Symbols Name Ready/Stable symbol Battery indicator ↓ Low battery indicator Description This symbol is displayed when the measurement display is stable. The normal battery power indicator with charge remaining If this symbol is displayed, replace all four batteries with new ones. WEEE label CE mark Automatic Power-Off Function The scale has an “Automatic power-off” function. If “0.00 kg /0.
Installing (or Replacing) the Batteries Caution Insert each battery with its positive (+) and negative (-) terminals properly aligned with the corresponding symbols in the battery compartment. Improper installation of the batteries may cause battery leakage. Replace all four batteries with new ones, when the symbol is displayed. Do not mix new and used batteries. It may cause damage to the scale or shorten the battery life. The symbol does not appear when the batteries are completely drained.
Setting the Unit Setting the unit manually 1. Confirm that the scale is turned off. Press the SET switch. The scale beeps and displays the unit currently set. Press the SET switch. SET switch 2. Press the SET switch to select the unit. 3. After three seconds of non-operation, the scale confirms the selected unit with two beeps, displays “ ” and automatically turns off. Setting the unit by the communication device (Only for devices that rewriting of the unit information is enabled.
Measuring Your Weight Using the NFC Function After measurement, the communication device receives the data. 1. Confirm that the scale is turned off. Step on the scale gently and stand still during the measurement. The scale turns on, displays all of the display segments. 2. Wait the finish of the measurement. The process of the measurement is displayed with segment “ ”. Turn off Step on the scale. In processing of measurement. 3.
Maintaining the Scale Clean the scale with a soft dry cloth or a cloth moistened with water and a mild detergent. Never use alcohol, benzene, thinner or other harsh chemicals to clean the scale. Remove the batteries from the battery compartment, when the scale is not going to be used for a long time. Before Requesting Service Problems is displayed. is displayed is displayed. is displayed. is displayed. is displayed. is displayed. is displayed.
Caution on Using the NFC Function The scale has an NFC Forum Type 3 Tag wireless interface module built in. When the scale is used near wireless communication devices which use the same frequency as that of the scale (13.56 MHz) or use its harmonic frequencies, electromagnetic interference may occur. In that case, turn off the devices that are not in use, or place the devices 1 meter or more away from the scale.
1-243 Asahi, Kitamoto-shi, Saitama 364-8585 JAPAN Telephone: [81] (48) 593-1111 Fax: [81] (48) 593-1119 A&D INSTRUMENTS LTD. Unit 24/26 Blacklands Way, Abingdon Business Park, Abingdon, Oxfordshire OX14 1DY United Kingdom Telephone: [44] (1235) 550420 Fax: [44] (1235) 550485 A&D ENGINEERING, INC. 1756 Automation Parkway, San Jose, California 95131 U.S.A. Telephone: [1] (408) 263-5333 Fax: [1] (408)263-0119 A&D Australasia Pty Ltd.