Installation Guide
Residen al Standard Gas Ultra Low Nox Water Heater Use and Care Guide • 35
MAINTENANCE
6
Reconnect the manifold
tubing (3/4” wrench), pilot
tubing (7/16” wrench) to the
gas control valve/thermostat. Also
reconnect the FV sensor wires, wiring
harness, and igniter wire. (See Figure
46 for the correct posi on of each
connec on.) Do not cross-thread or
apply any thread sealant to the fi ngs.
7
Reconnect the igniter wire.
8
Follow the “Ligh ng Instruc-
ons” on page 23.
9
Check for leaks with the main
burner on by brushing on an
approved noncorrosive leak
detec on solu on. Bubbles forming
indicate a leak. Correct any leak found.
IMPORTANT: All leaks must be fi xed
immediately.
10
Replace the outer door.
Cleaning the
Combus on Chamber
and Flame-arrestor
See also “Inspect and Clean the Air
Filter” on page 32.
1
Follow the steps in “Remov-
ing the Manifold/Burner
Assembly” on page 34.
2
Use a vacuum cleaner/shop
vac to remove all loose debris
in the combus on chamber
(Figure 52). Use compressed air to
clear any dust or debris that may have
accumulated in the fl ame-arrestor.
3
Follow the steps in “Replacing
the Manifold/Burner Assem-
bly” on page 34.
COMBUSTION CHAMBER
Figure 52 - Combustion chamber
MAINTENANCE