6 Becton Bunny & Becton 7 MK2 Gas stoves
OPERATING INSTRUCTIONS
FIRE DIMENSIONS
FITTING THE REFLECTIVE
PANELS
Becton Bunny. The panels are already installed.
Becton 7. The reflective panels supplied are to be
installed into the fire before the coal matrix is fitted.
The panels are hung on the lugs located inside the top
of the firebox on either side; the panel simply hooks
over the lug. The panels should be angled in line with
the bracket, so that the rear of the panels are pointing
towards the centre of the fire.
Once the reflective panels are fitted, arrange the
coals. See “Arranging the coals”
Category I
2H
For use in GB and IE at a
supply pressure of 20mbar
TECHNICAL DATA
Becton
Bunny
Natural Gas
Becton 7
Natural
Gas
Main Burner
Injector
Max. Heat
Setting
Heat Input
(net)
3.3 kW
4.2 kW
Heat Output
(net)
Gas Rate
0.349
m
3
/hour
0.444
m
3
/hour
Cold Setting
Pressure
1.5mb
3.5mb
Min. Heat
Setting
2.0 kW
2.6 kW
Bray 82-700
Bray 82-700
Aeromatic
AC13/112511
(mod 263)
Aeromatic
AC13/112511
(mod 263)
2.2 kW
2.8 kW
Heat Input
(net)
Heat Output
(net)
1.4 kW 1.8 kW
Gas Rate
0.211
m
3/
hour
0.275
m
3
/hour
NOx CLASS
CLASS 4
CLASS 4
293mm
Fig. 2