Hardware Manual

Table Of Contents
154 Technical data
Derating
Ambient temperature derating
IP21 (UL Type 1) drive types and other IP55 (UL Type 12) types than listed in the
following subheadings
In the temperature range +40…55 °C (+104…131 °F), the rated output current is
derated by 1% for every added 1 °C (1.8 °F). The output current can be calculated by
multiplying the current given in the rating table by the derating factor (k):
IP55 (UL Type 12) drive types -274A-2, 293A-3, -260A-5, -302A-5 and -174A-7
In the temperature range +40…45 °C (+104…113 °F), the rated output current is
derated by 1% for every added 1 °C (1.8 °F). In the temperature range +45…55 °C
(+113…131 °F), the rated output current is derated by 2.5% for every added 1 °C
(1.8 °F). The output current can be calculated by multiplying the current given in the
rating table by the derating factor (k):
T
1.00
0.90
+40 °C
+104 °F
+50 °C
+122 °F
k
+55 °C
+131 °F
0.80
-15 °C
+5°F
0.85
0.95
T
1.00
0.90
+40 °C
+104 °F
+50 °C
+122 °F
k
+55 °C
+131 °F
0.80
+45 °C
+113 °F
0.70
0.75
0.85
0.95
-15 °C
+5 °F