Hardware Manual

Table Of Contents
182 Technical data
Dimensions. weights and free space requirements
H1 Height with cable entry box.
H2 Height without cable entry box (option +P940)
H3 Height with hood
W Width with cable entry box
D Depth with cable entry box
* Hood increases height with 155 mm (6.10 in) in frames R4 to R8 and with 230 mm
(9.06 in) in frame R9.
** Hood increases width with 23 mm (0.91 in) in frames R4 and R5, 40 mm (1.57 in) in
frames R6 and R7 and 50 mm (1.97 in) in frames R8 and R9.
Note 1: For more information on dimensions, see chapter Dimension drawings.
Note 2: For dimensions of option +P940 and +P944, see ACS880-01 +P940/+P944 drives for
cabinet installation supplement (3AUA0000145446 [English]).
Note 3: For dimensions of option +C135, see Flange mounting kit installation supplement
(3AXD50000019100 [English]). For weights of the drive without cable entry box see ACS880-01
Frame IP21 UL type 1
H1 H2 W D Weight H1 H2 W D Weight
mm mm mm mm kg in. in. in. in. lb
R1 409 370 155 226 6 16.11 14.57 6.10 8.89 13
R2 409 370 155 249 8 16.11 14.57 6.10 9.80 18
R3 475 420 172 261 10 18.71 16.54 6.77 10.28 22
R4 576 490 203 274 18.5 22.70 19.30 7.99 10.80 41
R5 730 596 203 274 23 28.74 23.46 7.99 10.79 51
R6 726 569 251 357 45 28.60 22.40 9.92 14.09 99
R7 880 600 284 365 55 34.70 23.60 11.22 14.37 121
R8 963 681 300 386 70 37.90 26.82 11.81 15.21 154
R9 955 680 380 413 98 37.59 26.77 14.96 16.27 216
Frame IP55 UL type 12
H1 H2 W D Weight H1 * H3 W ** D Weight
mm mm mm mm kg in. in. in. in. lb
R1 450 - 162 292 6 17.72 - 6.38 11.50 20
R2 450 - 161 315 8 17.72 - 6.38 12.40 18
R3 525 - 180 327 10 20.70 - 7.09 12.87 22
R4 576 - 203 344 18.5 22.70 - 7.99 13.54 41
R5 730 - 203 344 23 28.73 - 7.99 13.54 51
R6 726 - 252 421 45 28.60 - 9.92 16.46 99
R7 880 - 284 423 55 34.66 - 11.18 16.65 121
R8 963 - 300 452 72 37.90 - 11.81 17.78 159
R9 955 - 380 477 100 37.59 - 14.96 18.78 220