Hardware Manual
Table Of Contents
- List of related manuals
- Table of contents
- Safety instructions
- Introduction to the manual
- Operation principle and hardware description
- Mechanical installation
- What this chapter contains
- Safety
- Examining the installation site
- Necessary tools
- Moving the drive
- Unpacking and examining the delivery (frames R1 to R5)
- Unpacking and examining the delivery (frames R6 to R9)
- Installing the drive
- Flange mounting
- Cabinet installation
- Cooling
- Grounding inside the cabinet
- Installing drives above one another
- Planning the electrical installation
- What this chapter contains
- Limitation of liability
- Selecting the supply disconnecting device
- Selecting and dimensioning the main contactor
- Checking the compatibility of the motor and drive
- Protecting the motor insulation and bearings
- Requirements table
- Additional requirements for ABB motors of types other than M2_, M3_, M4_, HX_ and AM_
- Additional requirements for ABB high-output and IP23 motors
- Additional requirements for non-ABB high-output and IP23 motors
- Additional data for calculating the rise time and the peak line-to-line voltage
- Additional note for sine filters
- Selecting the power cables
- Selecting the control cables
- Routing the cables
- Implementing thermal overload and short-circuit protection
- Protecting the drive against ground faults
- Connecting drives to a common DC system
- Implementing the Emergency stop function
- Implementing the Safe torque off function
- Implementing the safety functions with the FSO module
- Implementing the ATEX-certified Safe motor disconnection function (option +Q971)
- Implementing the Power-loss ride-through function
- Using power factor compensation capacitors with the drive
- Using a contactor between the drive and the motor
- Implementing a bypass connection
- Protecting the contacts of relay outputs
- Connecting a motor temperature sensor to the drive I/O
- Electrical installation
- What this chapter contains
- Warnings
- Checking the insulation of the assembly
- Checking the compatibility with IT (ungrounded) systems
- Connecting the power cables
- DC connection
- Connecting the control cables
- Connecting a PC
- Controlling several drives through panel bus
- Installing optional modules
- Installation checklist
- Start-up
- Fault tracing
- Maintenance
- What this chapter contains
- Maintenance intervals
- Heatsink
- Fans
- Replacing the main cooling fan of frames R1 to R3
- Replacing the auxiliary cooling fan of IP55 frames R1 to R3
- Replacing the main cooling fan of frames R4 and R5
- Replacing the auxiliary cooling fan of frames R4 and R5 (IP55 and option +C135) and IP21 frame R5 types ACS880-01-xxxx-7
- Replacing the main cooling fan of frames R6 to R8
- Replacing the auxiliary cooling fan of frames R6 to R9
- Replacing the IP55 auxiliary cooling fan of frames R8 and R9
- Replacing the main cooling fans of frame R9
- Replacing the drive (IP21, UL Type 1, frames R1 to R9)
- Capacitors
- Memory unit
- Replacing the control panel battery
- Replacing safety functions modules (FSO-12, option +Q973)
- Technical data
- What this chapter contains
- Marine type-approved drives (option +C132)
- Ratings
- Derating
- Ambient temperature derating
- IP21 (UL Type 1) drive types and other IP55 (UL Type 12) types than listed in the following subheadings
- IP55 (UL Type 12) drive types -274A-2, 293A-3, -260A-5, -302A-5 and -174A-7
- IP55 (UL Type 12) drive type -240A-5
- IP55 (UL Type 12) drive types -363A-3 and -361A-5
- IP55 (UL Type 12) drive type -210A-7
- IP55 (UL Type 12) types -0430A-3, -0414A-5 and -0271A-7
- Altitude derating
- Deratings for special settings in the drive control program
- Ambient temperature derating
- Fuses (IEC)
- Fuses (UL)
- Dimensions. weights and free space requirements
- Losses, cooling data and noise
- Terminal and lead-through data for the power cables
- Terminal data for the control cables
- Electrical power network specification
- Motor connection data
- Control unit (ZCU-12) connection data
- Efficiency
- Protection classes
- Ambient conditions
- Materials
- Applicable standards
- CE marking
- Compliance with the EN 61800-3:2004
- UL marking
- “C-tick” marking
- EAC marking
- Approvals
- Cyber security disclaimer
- Disclaimer
- Dimension drawings
- What this chapter contains
- Frame R1 (IP21, UL Type 1)
- Frame R1 (IP55, UL Type 12)
- Frame R2 (IP21, UL Type 1)
- Frame R2 (IP55, UL Type 12)
- Frame R3 (IP21, UL Type 1)
- Frame R3 (IP55, UL Type 12)
- Frame R4 (IP21, UL Type 1)
- Frame R4 (IP55, UL Type 12)
- Frame R5 (IP21, UL Type 1)
- Frame R5 (IP55, UL Type 12)
- Frame R6 (IP21, UL Type 1)
- Frame R6 (IP55, UL Type 12)
- Frame R7 (IP21, UL Type 1)
- Frame R7 (IP55, UL Type 12)
- Frame R8 (IP21, UL Type 1)
- Frame R8 (IP55, UL Type 12)
- Frame R9 (IP21, UL Type 1)
- Frame R9 (IP55, UL Type 12)
- Safe Torque off function
- Resistor braking
- What this chapter contains
- Operation principle and hardware description
- Planning the braking system
- Mechanical installation
- Electrical installation
- Start-up
- Technical data
- Dimensions and weights of external resistors
- Common mode, du/dt and sine filters
- Further information
260 Common mode, du/dt and sine filters
07A6-5 B84143V00011R229 7.0 5.3 122 90 212 72
11A0-5 B84143V00011R229 10.2 7.7 172 90 262 72
014A-5 B84143V0016R229 13 9.8 232 80 312 70
021A-5 B84143V0025R229 20 14.7 337 140 477 75
027A-5 B84143V0033R229 25 18.8 457 160 617 75
034A-5 B84143V0050R229 32 23.7 562 220 782 78
040A-5 B84143V0050R229 35 26.0 667 220 887 78
052A-5 B84143V0066R229 49 36.9 907 250 1157 78
065A-5 B84143V0066R229 60 45.1 1117 250 1367 78
077A-5 B84143V0075R229 62 46.3 1120 310 1430 78
096A-5 B84143V0130R230 80 60.6 1295 * 1295 80
124A-5 B84143V0130R230 104 78.7 1440 * 1440 80
156A-5
B84143V0162R229 140 105.8 1940 * 1940 80
180A-5
B84143V0162R229 162 121.8 2310 * 2310 80
240A-5 B84143V0230R229 205 154.3 3300 900 4200 80
260A-5 B84143V0230R229 221 166.7 3900 900 4800 80
361A-5 B84143V0390R229 289 217.9 4800 1570 6370 80
414A-5 B84143V0390R229 332 250.1 6000 1570 7570 80
U
N
= 690 V
07A3-7 B84143V0010R230 6.9 5.2 217 90 307 72
09A8-7 B84143V0010R230 9.3 7.0 284 90 374 72
14A2-7 B84143V0018R230 13.5 10.2 399 130 529 72
018A-7 B84143V0018R230 17.1 12.9 490 130 620 72
022A-7 B84143V0026R230 21 15.7 578 160 738 72
026A-7 B84143V0026R230 25 18.6 660 160 820 72
035A-7 B84143V0040R230 33 25.1 864 250 1114 75
042A-7 B84143V0040R230 40 30.1 998 250 1248 75
049A-7 B84143V0056R230 48 36.2 1120 290 1410 78
061A-7 B84143V0056R230 56 42.5 1295 290 1585 78
084A-7 B84143V0092R230 78 58.6 1440 610 2050 79
098A-7 B84143V0092R230 92 69.3 1940 610 2550 79
119A-7 B84143V0130R230 112 84.2 2310 * 2310 80
142A-7 B84143V0130R230 112 84.7 3300 * 3300 80
Drive
type
ACS880-
01-...
Sine filter type I
cont.
max
P
cont.
max
Heat dissipation Noise
Drive Filter Total
AkWWWWdB(A)