Product manual

:HOGLQJHTXLSPHQW
,QVWDOODWLRQ
30
Installation_eng.fm
,QVWDOODWLRQRIDFFHVVRULHV
&RROLQJXQLW2&(
(included in welding gun set PKI 500R and Binzel WH 455D)
Connect the cable bundle to the cooling unit as follows:
- Red water hose to the cooling unit’s return connection ,1.
- Blue water hose to the cooling unit’s feed connection 287.
- Air hose to the compressed air supply.
- Gas hose to the gas cylinder.
Connect the cooling unit’s mains cable as follows:
- For ESABMIG, RPB, LAF: The mains cable is connected to terminal
A202X3:5,6in the control cabinet.
- For LRB, LRC: The mains cable is connected to terminal
$X202:10,11in the control cabinet.
Fill the cooling unit with water and any anti-freeze (for detailed information
refer to the OCE 2 manual). Check the flow in the welding gun by opening
the cooling unit’s return hose connection,1 until water comes in.
If the water guard is ordered afterwards, the strap in the wire feed unit must
be removed before the guard can be used. This is done as follows:
- Unscrew the strap %\ on the terminal in the wire feed unit between con-
nections and .