6.5 Configuration
Programmable parameters enable the adaptation to different types of welding
equipment. The configuration parameters determine:
- the control properties
- the scale factors
- the offset values
- the max. and min. values, etc.
Flexible
A manual standard power source enabling remote control by way of ana-
logue references and with the on/off function, for example
ESABMIG 400/500t , RPB 320/420/520, LAF, Miller Delta Weld, etc.
A wire feeder of the DC type with AC/DC tachometer as speed feed-back.
ARCITEC
A wire feeder of the DC type with AC/DC tachometer as speed feed-back.
These factors are listed and their values can be edited under the menu: Misc\Sys-
tem\Parameters\IO signals\TypesUnits\PIB-name (=configured IO-name)
on the programming unit of the robot. Modified values are automatically trans-
ferred to the PIB board when restarting the robot.
:KHQFKDQJLQJWKH3,%, - Previous configuration parameters stored in the robot
will be automatically transferred to the new PIB card (([FHSWLRQVHHFKDSWHU
DQGVHFWLRQ).
Configuration data for ABB’s standard welding equipment are included in the AW
system configuration diskettes, which can be ordered according to the price list for
standard products.
See Appendix 1; Configuration parameters, where all the parameters are listed and
defined.
6.6 Options for Increased Functionality
PIB is prepared for connection of a supplementary board increasing the functional-
ity. The board is to be connected to a 32-pole connector of the Euro type. See Fig-
ure 19 on page 35.
Smartac (joint search and tracking device):
See section 6.15.