Product manual

3,%3URFHVV,QWHUIDFH%RDUG
48
PIB-M2001_eng.fm
TB3 - Connection to Power Source
TB4 - Connection to gun cleaner and TCP detector
* Common connection to the welding object and the power source, negative pole
for Smartac/PIB.
** PDM=Process Data Monitoring
'HVLJQDWLRQ )XQFWLRQ9ROWDJH 2XW ,Q ([SODQDWLRQ
1 Start Power Source A Closing contact x Control relay for power source
(or cooling fan, ARCITEC)
2 Start Power Source B Closing contact x Control relay for power source
(or. cooling fan, ARCITEC)
3 Weld ref. Analog 0-15 V x Reference for welding voltage
4 Ref. Common Analog common x Reference zero
5 Induct. Ref Analog 0-15 V x Reference for setting of the inductance
6 Weld Object Analog x Sensing the welding voltage on weld
object*
7 Arc Voltage Gun Analog x Return the welding voltage to power
source
8 Arc Voltage object Analog Sensing the welding voltage on weld
object for PDM**
9 24 V Ext Supply voltage x For external relay
10 0 V Supply voltage x For external relay
11 NC Not connected
'HVLJQDWLRQ )XQFWLRQ9ROWDJH 2XW ,Q ([SODQDWLRQ
1 24V DC Supply x
2 0V DC Supply, zero x
3 Lubrication Digital 24V DC x Lubrication for cleaning reamer
4 Cleaning Digital 24V DC x Cleaning reamer
5 Wire Cutter Digital 24V DC x Cutting the wire
6 Cleaning finished Digital 24V DC x Cleaning finished
7 Bulls Eye Digital 24V DC x TCP search stop