Product manual

3,%3URFHVV,QWHUIDFH%RDUG
50
PIB-M2001_eng.fm
TB6 - Connection 2 to Wire Feed Unit
TB11
'HVLJQDWLRQ )XQFWLRQ9ROWDJH 2XW ,Q ([SODQDWLRQ
1 Gun reset 24V DC x Resetting the collision sensor
2 Gun Crash 24V DC x Collision sensor
3 Current Sense 24V DC x Welding current sensor
4 Water Flow 24V DC x Water flow sensor
5 Gas Flow 24V DC x Gas flow sensor
6 NC NC Bridged with TB 6/10
7 Encoder TG INPUT DC Puls x DC- or AC-tacho/input for encoder
tacho
8 Man. Wire Feed 24/DC x Manual wire feed
9 + 24 V Supply voltage x Supply voltage
10 0 V Supply voltage x Supply voltage/ common for enco-
der tacho
11 Temp PTC Analog x Temperature sensor in wire fed unit
12 Aux Motor 24V DC x Control signal for Push feed unit
13 PDM Tacho + AC/DC x Tacho for Process data monitoring
14 PDM Tacho - AC/DC x Tacho for Process data monitoring
15 + 5V alt + 15V DC x Supply voltage for encoder tacho
'HVLJQDWLRQ )XQFWLRQ9ROWDJH 2XW ,Q ([SODQDWLRQ
1 Weld Current A Analog x Shunt connection for PDM
2 Weld Current A Analog x Shunt connection for PDM
3 HF Ignition 24V DC x Indication of HF ignition, Option
4 Smartac sense detect 24V DC x Alternative for sens. detect. via
CAN-bus