Product manual

3,%3URFHVV,QWHUIDFH%RDUG
52
PIB-M2001_eng.fm
6.13 Technical Specification
6.13.1 Mechanical Data
Dimensions: 257x196x72.5 mm
Weight: 2.1 kg
Enclosure class: IP 20
6.13.2 Electrical Data
Power supply: See Figure 24 on page 53 - Transformers.
Digital outputs: Continuous load/output: max. 350 mA.
Total output load: max. 1.6 A, < 70°C.
Tripping of overload protection per output: 370 mA.
Remark: Regarding capacitive load > 0.05 uF a temporary overload can arise at
the start causing the overload protection to trip. If this occurs a current-limiting
resistor must be connected in series with the connected load.
Digital inputs 24V DC: Incoming voltage, switch on: 15 to 35V.
Incoming voltage, switch off: -35 to +5V.
Incoming impedance, 4 kohm, resistive.
42V AC outputs: Max. current: 1A at < 70°C.
Relay outputs: Max. voltage: 250V AC.
Max. current: 10 A.
Note: Sparc protection has to be externally connected.
Analog outputs: Outgoing voltage: 0 - 15 V, < = 100 mA, < = 70°C.
6.13.3 Environmental Data
Temperature data:
EMC: (ElectroMagnetic Compatibility) According to standard EN 50199.
LVD: (Low Voltage Directive) According to LVD standard EN 60204.
Storage Operation According to
Cold 40° C, 16h +5° C, 2 h IEC 68-2-1
Heat +70° C, 16 h
+70° C, 2 h IEC 68-2-2
Change – 40° C / +70° C, 2 cycles
IEC 68-2-14