7.0.1 Table Configuration parameters
3DUDPHWHUQDPH 3DUDPHWHUQDPH
LQWHDFKSHQGDQW
3DUDPHWHUEHKDYLRU 3DUDPHWHU
UDQJHGHQRPLQDWLRQ
Software Revision SoftwareRevison Current software revison
(readonly)
-
Motor Max Voltage MotorMaxVoltage Maximum allowed voltage for the
DC-motor connected.
{0...110} V
Motor Current Limit MotorCurrentLim Maximum allowed current for the
DC-motor connected.
{0...100} 0.1 A
0RWRU0D[6SHHG MotorMaxSpeed Maximum allowed setting for motor
speed in motor speed quantity units
{0...500} 0.1
0RWRU0LQ6SHHG MotorMinSpeed Minimum allowed setting for motor
speed in motor speed quantity units
{0...500} 0.1
0RWRU5HJXODWRU
3IDFWRU
MotorRegPFactor Proportional factor of the motor
speed PI regulator.
{0...100} %
0RWRU5HJXODWRU
,IDFWRU
MotorRegIFactor Integrating factor of the motor speed
PI regulator.
{0...100} %
0RWRU5HJXODWRU
)HHGIRUZDUGIDFWRU
MotorFeedForwar
d
Feedforward factor of the motor
speed PI regulator.
{0...100} %
Motor Temp Limit MotorTempLimit Maximum allowed temperature for
the motor.
{0...255} °C
0RWRU%UDNH5DWLR MotorBreakRatio Defines the duty cycle of the brake
transistor .
{0...255} 0 = No brake.
255 = Full brake
Motor Control Error
Time Limit
MotorCtrlErrTime
Lim
Defines the maximum allowed time
for difference between motor speed
set value and actual value before
setting the alarm
{0...255} 1/10 s
0RWRU7DFKR
&RQYHUVLRQ)DFWRU
MotorTachoConv For AC: 100 Frequency in Hz for 1
motor speed quantity.
For DC: 10000 Voltage in V for 1
motor speed quantity.
{0...65535}
AC (tacho type 0) : 0.01 Hz
/ motor speed quantity
AC fast (tacho type 2): 0.02
Hz / motor speed quantity
DC (tacho yype 1): e-4 V /
motor speed quantity
0RWRU7DFKR
7\SH
MotorTachoType Determines type of tacho connected
and used by the motor speed
regulator of the PIB. Valid types are
AC-tacho and DC-tacho
{0,1}
0 (AC-tacho)
1 (DC-tacho)
2 (Fast AC-tacho)
Motor DC Offset MotorTachoDCOff
set
Motor speed offset for DC-tacho
connected
{-1000...1000} 0.01 m/min
(Or r/min, l/min)