Owner manual

5
1. Main features
8 programmable zones
tamper monitoring
simple connection using 4-wire BUS
compatible to TERXON M / MX
2. Installation
1. Open the housing of the hardwired expansion unit.
2. Release the 3 screws and remove the PCB from the
rear wall of the unit.
3. Use the rear of the hardwired expansion unit to draw
the boreholes at the required assembly location. Bore
the appropriate holes and insert the correct dowel pins
into then.
4. Insert the cable of the 4-wire BUS as well as the
required cable from the zones through the two larger
holes on the rear of the module.
5. Screw the rear of the housing with the correct screws
onto the required assembly location and re-insert the
PCB.
6. Make sure that the alarm centre is disconnected from
the mains.
7. Connect the 4-wire BUS and the zones correctly,
depending on the zone type.
8. Once more close the 8-zone expansion module.