Installation User guide

53
UK
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
077 Alarm behaviour for internal (D)
To change the alarm property for internal active (D):
1. On the control unit, enter:
077
2. The LCD display shows: 077: D = Internal
3. Via the keypad, select from the following items
and press:
0
D=Keypad
Only the control units are activated.
1
D=Internal
On alarm, the control units and the
internal alarm are activated.
2
D=Local
On alarm, the control units, the internal
alarm and the external siren are
activated.
3
D=Full
On alarm, the control units, the internal
signalling, the external sirens and the
exits are activated.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
079 Exit delay time internal D
To change the property of the exit delay time for internal
active D:
1. On the control unit, enter:
079
2. The LCD display shows: 079: Exit D=10
3. Via the keypad, select from the following items
and press:
1
Exit D=10
Exit delay time for
internal active D: 10 seconds.
2
Exit D=20
Exit delay time for
internal active D: 20 seconds.
3
Exit D=30
Exit delay time for
internal active D: 30 seconds.
4
Exit D=45
Exit delay time for
internal active D: 45 seconds.
5
Exit D=60
Exit delay time for
internal active D: 60 seconds.
6
Exit D=120
Exit delay time for
internal active D: 120 seconds.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.