FURM35000A Smartvest Wireless Smoke/Heat Detector User Manual GB 16 0359 0359-CPR-00493 EN 14604:2005/AC:2008 Version 1.
Contents Introduction...................................................................................... 4 Safety information ........................................................................... 6 Scope of delivery ............................................................................. 9 Technical data .................................................................................. 9 Functional principle and features .................................................
Contents Declaration of performance ...........................................................
Introduction Introduction Information on user manual Dear Customer, Thank you for choosing our product and putting your trust in us. You've made a good choice. This smoke alarm device (hereinafter referred to as “detector” or “device”) has been developed with great care and manufactured to assist you in swiftly detecting the danger of a fire. Please read this user manual in its entirety and follow all instructions to ensure optimal handling of the device.
Introduction Limitation of liability Your rights are limited to the repair or replacement of this product in its asdelivered condition.
Safety information Safety information Explanation of symbols The following symbols are used in this manual and on the device: Symbol Signal word Caution Meaning Indicates a risk of injury or health hazards. Caution Indicates a risk of injury or health hazards caused by electrical voltage. Important Indicates possible damage to the device/accessories. Note Indicates important information.
Safety information Information on the battery The device is powered by two 1.5 V AA replaceable batteries. High direct heat may damage the batteries. For this reason, you should not place the device on heat sources (such as radiators) or in direct sunlight. The batteries cannot be recharged. Batteries should only be removed in order to be changed, otherwise the device cannot warn you of a serious incident.
Safety information Packaging Keep packaging material and small parts away from children. There is a risk of suffocation. Remove all packaging material before using the device. Functioning of the device To ensure that the device functions correctly, please note the following points: Do not cover the device. Do not paint over the device or cover it with wallpaper. Do not, on any account, open or repair the device. Failure to observe this instruction will invalidate the warranty.
Functional principle and features Scope of delivery ABUS smoke alarm device including batteries User manual Installation material Technical data Power supply Smoke detection Heat detection Power consumption Operating temperature Humidity Sound pressure Alarm muting Detection range Installation location Radio frequency 2 x 1.
Scope of delivery | Technical data Functional principle and features The smoke alarm device does not detect gas, steam, fire or flames. People with impaired hearing may not be able to hear the alarm. Alarms with additional optical signalling are available for such cases. Particularly high electromagnetic radiation could impair the function of the detector. For this reason, do not install the detector near magnets or devices which produce electromagnetic radiation.
Behaviour in case of alarm | Selecting location Behaviour in case of alarm (1) Alert all occupants. (2) Help children as well as disabled, elderly and sick people. (3) Close all windows and doors behind you. (4) Leave the house immediately. (5) Do not use lifts. (6) Alert the fire service: Tel. 112.
Selecting location Smoke alarm devices are to be used as the bare minimum RM equipment in all bedrooms, children's rooms and hallways which act as escape routes, and are to be installed in each case in the middle of the room, on the ceiling only (do not install on a wall) (Fig. 2). Select the highest installation location with a minimum distance of 50 cm to surrounding walls, furniture and lamps. Configuration is optimal RM when devices are located in all other rooms as well as staircases.
Installation and start-up Installation and start-up Take the following steps in the specified order to install the detector on the ceiling: 1. Loosen the smoke alarm device from the housing base by turning it anticlockwise. 2. Insert the batteries, ensuring that the polarity is correct. 3. Mark drill holes through the housing base. 4. Drill the necessary holes and attach the screw anchors, then screw on the detector base.
Installation and start-up 5. Mount the smoke alarm device on the detector base by turning it clockwise. Failure to follow the instructions for the selection of a location and installation may result in risk of injury, e.g. from smoke alarm devices falling down.
Displays and functions Displays and functions Normal state In the normal state, the red control LED under the housing cover flashes once every 40 seconds and signals that the detector is ready for operation.
Displays and functions Testing the device electronics Regularly check the functionality of the smoke alarm device by pressing the Test button. The warning tone signals and the red “ALARM” LED flashes. This does not indicate that smoke is present in the air in the room; it is a confirmation that the smoke alarm device is functioning properly. Test the functionality of the detector after installation without fail. A regular test is also recommended. Keep the device at arm's length to protect your hearing.
Displays and functions If the detector's battery charge falls below a certain value, the detector signals this with an acoustic warning tone (every 40 seconds). If this warning signal sounds, the detector batteries must be immediately replaced with new batteries. Pressing the Test button mutes the fault signal for 8 hours. From the time of the first battery warning signal, the detector is still operable and completely functional for at least 30 more days.
Displays and functions Alarm state: Smoke If smoke is detected, a loud, pulsing alarm tone sounds and the red LED flashes at the same time at short intervals. In this case, proceed as described in the “Behaviour in case of alarm” chapter. Alarm tone 0.5 s – pause 0.5 s – alarm tone 0.5 s – pause 0.5 s – alarm tone 0.5 s – pause 1.5 s Alarm state: Heat If heat is detected, a loud, pulsing alarm tone sounds and the red LED flashes at the same time at short intervals.
Displays and functions At the same time, the detector receiving notification of the alarm checks to see how long the other detector has been sending the remote notification. The pulsing alarm tone will stop sounding 60 seconds after the detector which triggered the alarm is muted. To reduce this time, the pulsing alarm tone can be stopped after just 30 seconds by pressing the Test button (for 1 second).
Displays and functions Alarm muting function (hush mode) If the detector is in the alarm state, the acoustic alarm can be deactivated for 8 minutes by pressing the Test button. If the muting function is active, the red LED flashes every 8 seconds. If smoke is still detected in the smoke measurement chamber after the 8-minute muting period, the acoustic alarm will sound again.
Displays and functions Connecting the detector to the Smartvest alarm panel The wireless Smartvest smoke/heat detector can be connected to a Smartvest alarm panel. To do this, follow the instructions in the Smartvest app. The teach-in process must first be initiated in the app. The batteries are then inserted in the detector and the connection is established between the detector and the alarm panel.
Displays and functions Connecting the detector to identical detectors The wireless Smartvest smoke/heat detector can also be connected to other wireless Smartvest smoke/heat detectors without a Smartvest alarm panel. To do this, follow these steps: 1. Define one detector as the central detector. 2. Insert the batteries into the central detector and wait 3 seconds. 3. Press and hold the Test button on the central detector for more than 10 seconds until the LED starts flashing quickly.
Displays and functions 6. Press the Test button for 15 seconds to reset the smoke detector to the factory default settings and to end the connection to the other smoke alarm devices.
Care and maintenance Care and maintenance What should you do in the event of a false alarm? Possible reasons for a false alarm are: Welding and cutting work, soldering and other high-temperature work, sawing and grinding, dust from construction work or cleaning, extreme electromagnetic effects, and temperature fluctuations which lead to condensation of the humidity in the detector.
Care and maintenance Dusty detectors must be cleaned. You can clean dust from the air vents of the detector using a vacuum cleaner or compressed air. If necessary, you can remove the dust with a brush. You can clean the surface using a cloth slightly dampened in soapy water. Do not allow water to enter the inside of the device. Do not clean the device in a dishwasher. Do not use sharp, pointed, abrasive or corrosive cleaning materials, chemicals or hard brushes.
Care and maintenance Changing the battery Turn the detector anticlockwise and remove it from the mount. Remove the old batteries. Insert two new batteries, ensuring that the polarity is correct. Test the smoke alarm device. To do so, press and hold the Test button for > 5 seconds; the detector repeats the pattern: 3 alarm tones, 1.5-second pause. Turn the detector clockwise onto the mount.
Warranty Warranty ABUS products are designed and manufactured with the greatest care and tested according to the applicable regulations. The warranty only covers defects caused by material or manufacturing errors at the time of sale. If there are demonstrable material or manufacturing errors, the smoke alarm device will be repaired or replaced at the warrantor's discretion. In such cases, the warranty ends when the original warranty period of 2 years expires.
Warranty | Disposal problem must be supplied along with the smoke alarm device in question. If you discover a defect on your smoke alarm device which existed at the time of purchase, contact your dealer directly within the first two years. Disposal Dispose of the device in accordance with EC Directive 2002/96/EC – WEEE (Waste Electrical and Electronic Equipment). If you have any questions, please contact the municipal authority responsible for disposal.
Declaration of conformity | Declaration of performance Declaration of conformity ABUS Security-Center GmbH & Co.