Display:
The following values are apparent on the display during a charging process:
Program (Charge, Charge Test, Discharge Test)
Battery Voltage (V)
Capacity (mAh)
Elapsed time (hh:mm)
Internal resistance (mR)
Charging current (mA)
„End“ (Appears if actual charging process finished)
Channel number
Display Description
Function Description:
You can choose the following programs:
Charge
In this program you can charge the inserted batteries.
Charge-Test
With „Charge-Test” program you can measure the charged capacity of the batteries. The
charger discharges the batteries in the first step, during the discharge process the LC Display
starts to count the discharged capacity. After that, the battery gets charged completely in the
2
nd
step. Both capacity values (discharged as charged) are stored in the charger’s memory
and can be retrieved after finish. So this test consists of the following steps:
1) Discharge (The capacity gets measured and stored and is available after end of the
test)
2) Charge (The capacity gets measured and stored and is also available after end of the
test)
If the channel button gets pressed for the first time, only the display lights up. After
pressing it again, the shown capacity on the display switches between the measured
charging and discharging capacity. Which one of them is displayed, is symbolized by the
English