DETAILS
CATHODE T100
Product
(1) For our lower output system; T50, contact ACL. For a 1 lamp standard ballast system see B100. For a 2 lamp high output ballast system see B200.
(2) For multiple selections place a comma after each selection.
Standard Output
7 Lamp Transformer
Cold Cathode System
T100
___ ___
S01
(2)
DI - Dim
ND - Non Dim
S - Surface
Standard Color (s) Dim-able MountPrimaryEnvironment
120V
277V -Special
Order
Note: For a variation (custom) of this product contact ACL to request a variation number and information.
SPECIFICATION CODE:
DR - Dry
DP - Damp
See Chart
(1)
S01
Project Name
Linear FeetDate
S
NTS
Single Row Closed Loop
CATHODE T100 PRODUCT DETAILS:
date: August 21, 2008
sheet description: Single Row Closed Loop
file: T100details.pdf
page:
1
A. Transformer
B. Lamp
C. Intermediate
Lampholder
D. Feed Lampholder
E. GTO-15 in Conduit
F. Cove
G. Upper Ceiling
H. Lower Ceiling
I. Lamp Support
F
G
B
I
C
D
E
A
H
System Requirements
1. Secondary feeds must be equal in length and not exceed 20’
2. Only one single GTO-15 conductor for each conduit feed
3. Maximum length of lamp is 94”
4. Lamp lengths shall be standardized when ever possible
5. Transformer installed in accessable and vented area(s)
6. Sound rating approximately 33 decibels
7. Include detail(s) when possible
Note: Additional rows of lamps can be specified
either in whites or separate colors.
T100 Specifications
Seven Lamp Transformer NPF 120mA
(1) For 277V and HPF contact ACL.
(2) Use VA for computing loads. Use Watts for computing power consumption.
X
Y
Z
4.625”
17.625”
8.0”
Z
Y
X
VA AMPS Sec.V
1080 9.4 9000
900 7.8 7500
600 5.2 5000