Owner's manual

25-62-03
Page 47 of 87
JUN 20/13
ACR ELECTRONICS, INC / ARTEX PRODUCTS
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
B406-4 (453-5004)
TASK 25-62-03-810-801
3. Troubleshooting
SUBTASK 25-62-03-810-001
A. Self-Test Error Troubleshooting Guidelines
(1) Table 6 describes the ELT self-test LED error codes (i.e., flash codes), their probable causes,
and possible solutions. The 5-flash error is not present when the ELT is programmed with a
serial user protocol (short message).
NOTE
: Upon activation, the LED will display a long single flash, which is normal. Any self-
test error codes will display following this initial flash. Do not confuse the initial flash
with a 1-flash error code. If there are multiple errors, there is a 0.5 to 1.0 second
pause between each error code.