Owner's manual

ACR ELECTRONICS, INC / ARTEX PRODUCTS
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
B406-4 (453-5004)
25-62-03
Page 50 of 87
JUN 20/13
SUBTASK 25-62-03-810-002
B. ELT Troubleshooting Guidelines
(1) Table 7 provides ELT troubleshooting guidelines for installation and operational issues.
Table 7 ELT Troubleshooting Guide
SYMPTOM PROBABLE CAUSE POSSIBLE SOLUTION
Remote panel status light always
on (steady)
Improper wiring Verify wiring
Short circuit
Check for frayed insulation
Verify integrity of all crimp and
solder connections
ELT will not turn off
Battery too low to support 406
burst and causes circuit to reset
Remove battery pack to disable
ELT and replace battery pack
Turn off ELT using local switch - If ELT turns off:
Defective remote panel harness
reset circuit wiring
Check wiring continuity and
repair as necessary
Defective remote switch Replace remote panel
If ELT does not turn off using local switch:
ELT defective
Remove battery pack to disable
ELT and return ELT to factory for
servicing