Owner manual

25-69-10
Page 43 of 58
APR 30/12
ARTEX PRODUCTS / ACR ELECTRONICS, INC.
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
453-6500
TASK 25-69-10-450-802
2. Mechanical
SUBTASK 25-69-10-450-001
A. Chassis Location
CAUTION
: AVOID LOCATING THE ELT/NAV INTERFACE WHERE IT MAY BE SUBJECTED TO
UNPROTECTED EXPOSURE TO HARSH CHEMICAL FLUIDS, SUCH AS DEICING
COMPOUNDS. THESE TYPES OF CHEMICALS MAY CAUSE DAMAGE TO FASTENERS AND
ELECTRICAL COMPONENTS, AS WELL AS ELECTRICAL CONNECTOR CORROSION.
(1) Mount the ELT/NAV Interface within 2 feet (610 mm) of the ELT, such that the interface
harness does not exceed 3 feet (914 mm) including strain relief.
(2) The ELT/NAV Interface chassis and ELT are mounted to the same support structure in most
installations.
SUBTASK 25-69-10-450-002
B. Chassis Installation
(1) Coordinate ELT/NAV Interface chassis installation with ELT installation whenever possible. If
the ELT/NAV Interface is an add-on to an existing ELT installation, extend/modify the existing
ELT support structure to accommodate the ELT/NAV Interface.
(2) See "Figure 6. ELT/NAV Interface Outline and Dimensions".
Figure 6. ELT/NAV Interface Outline and Dimensions
2.00
(51)
2.00
(51)
5.00
(127)
8.30 (211)
8.90 (226)
9.25 (235)
2.75
(70)
9.57 (243)
1.15
(29)
5.27 (134)
1.88
(48)
Dimensions in inches (mm) - Tolerances ±0.020 (0.5) except as noted
453-6500
0.25
(6)
P1
P2
Ø 0.187 (4.7)
±0.005 (0.13)
(6 PLCS)