PRODUCT SUPPORT MANUAL RCL-50 // Remote Control Searchlight System Model No.: RCL-50 Product No.: 1939.3, 1940.3 Y1-03-0141 Rev. F ACR Electronics, Inc., // 5757 Ravenswood Road // Fort Lauderdale // FL // 33312-6645 T: +1 (954) 981-3333 // F: +1(954) 983-5087 // www.acracrtex.
CAUTION: Before proceeding to install, test or use your new ACR Electronics product, please read this Product Support Manual in its entirety. If you have questions regarding the contents of the manual, please contact our Technical Service Department at ACR Electronics, Inc., Telephone +1 (954) 981-3333 or email service@acrartex.com. Please be ready to provide the technician with the page number you wish to discuss.
Table of Contents SECTION 1- FOREWORD _____________________________________ 3 SECTION 2- GENERAL________________________________________ 4 SECTION 3- SEARCHLIGHT ____________________________________ 4 SECTION 4- REMOTE CONTROL SYSTEM _________________________ 5 SECTION 5- URP-102 POINT PAD™ _____________________________ 5 SECTION 6- URC-102 Master Controller _________________________ 9 APPENDIX B- BULB REPLACEMENT PROCEDURE _________________ 14 APPENDIX C- PRODUCT COMPONENTS ________________________ 15 APP
RCL-50B, 12/24V REMOTE CONTROL SEARCHLIGHT SYSTEM SEARCHLIGHT Figure 1- Remote Control Searchlight System SECTION 1 - FOREWORD Congratulations and thank you for purchasing the ACR RCL-50B Searchlight. The combination of computer aided design, high quality raw materials, and quality-controlled manufacturing produce a superior product. The Test Facility at ACR can reproduce some of the harshest environmental conditions known to man.
SECTION 2 - GENERAL The RCL-50B was specially designed for mariners who require a high intensity remote controlled searchlight that can stand up to the tough marine environment. The RCL-50B searchlight system contains a narrow beam searchlight that produces 80,000 peak candle power by combining a 55W halogen lamp on the 12V version or a 70W halogen lamp on the 24V version with our unique optical quality parabolic reflector.
SECTION 4 - REMOTE CONTROL SYSTEM The Remote Control System consists of the URC-102 Master Controller and the URP102 Point Pad™. This system is compatible with 12 VDC and 24 VDC systems without modification. The remote control system may be used with 12 V or 24 V searchlights, Only the lamp in the light head assembly must be changed to match the voltage rating. SECTION 5 - URP-102 POINT PAD™ Case Options The URP-102 Point Pad™ is supplied as a surface mount unit (see Figure 4).
Additional Point Pads™ (up to three (3) pads) may be used with one (1) Master Controller. A standard "T" connector or RG-59 television type "splitter" is used for each additional Point Pad (see Figure 2). Limit the total length of all coax cable used to 300 feet. The URP-102 Point Pad™ is backwards compatible with all RCL-100/50 searchlights and with the URC-101 Master Controller. CAUTION: The URP-102 Point Pad™ is not recommended for use with the first generation URC-100 Master Controllers.
Figure 3- URP-102 Point Pad™ Functions URP-102 Point Pad Functions Press the ON/OFF button to turn the lights ON or OFF. Press the SPEED button to toggle between High and Low rotation speeds. Press the Right or Left Arrows to rotate the Searchlight in that direction. Press the Up or Down Arrows to raise or lower the Searchlight-beam. To activate the XRCiZ™ feature, press and hold the ON/OFF button for greater than 5 seconds. The green LED indicates XRCiZ™ feature is enabled.
Figure 4- URP-102 Point Pad™ Surface Mount Case Figure 5- URP-102 Point Pad™ Flush Mount Case Y1-03-0141F 8
Figure 6- URP-102 Point Pad™ Surface Mount Case with gasket and Flush Mount Case with gasket SECTION 6- URC-102 Master Controller Mounting The Master Controller can be mounted in any position near the searchlight that is protected from the weather. Check in advance that the coax cable from the Point Pad™ and the wiring harness from the searchlight can be routed to this location. Mount the Master Controller with the wires and coax facing down. Use an appropriate fastener for your mounting location.
WARNING: This wire MUST be fused with a 15 amp fuse in the Master Controller's in-line fuse-holder. Wiring to Searchlight The RCL-50B searchlight is supplied with a 12-foot integral wire harness. This wire harness is cut to this length specifically to allow for a voltage drop. Shortening the harness will decrease the life of the bulbs. Any extra length of wire harness should be loosely coiled in a convenient place.
The URC-102 Master Controller has the unique XRCiZ™ feature. The XRCiZ™ feature routinely operates all moving parts in the searchlight to keep the motors and drive mechanism freely running. Once activated, and every 30 days thereafter, the XRCiZ™ feature wakes up and operates the searchlight. The searchlight will rotate 360 in both directions and the parabolic reflectors will move to the full up and down positions.
Power Source Fuse Spotlight 12 VDC or 24 VDC Master Controller in-line 15 amp fuse Ground Blue Orange Master Yellow Green Red White Brown Black Lamp Power Lamp Ground Spot Up Spot Down Spot Left Spot Right 75 ohm TV Coaxial Cable “T” Connector or Optional 75 Ohm Splitter for Multiple RCL-100 Point Pads Other RCL-100 Point Pads 75 ohm TV Coaxial Cable RCL-100 Point Pad Note: Wiring must be in accordance with this diagram. Improper wiring will damage components.
Figure 8 - URC-102 Master Controller Y1-03-0141F 13
APPENDIX A- RCL-50B SPECIFICATIONS (with URC-102 Controller) Specification 12V Unit 24V Unit Mirror diameter 4in (10.16cm) 4in (10.
APPENDIX C- PRODUCT COMPONENTS Product No. 1939.
APPENDIX D- ACCESSORY COMPONENTS Product No. 1927.3 - URC-102 Master Controller Installation Kit includes: Description Master Controller, URC-102 Quantity 1 ACR Part Number A3-06-2231 Connector, "In-Line" 8 A1-03-0222 Instruction Sheet, Master Controller 1 Y1-06-0178 Product No. 1928.
Product No. 9282.
APPENDIX E - WARRANTY, NOTICES Limited Warranty This product is warranted against factory defects in material and workmanship for a period of 1 (one) year* from date of purchase or receipt as a gift. During the warranty period ACR Electronics, Inc. will repair or, at its option, replace the unit at no cost to you for labor, materials and return transportation from ACR. For further assistance, please contact our Technical Service Department at ACR Electronics, Inc.
EC DECLARATION OF CONFORMITY ACR Electronics, Inc. hereby declares that the following product is in conformity with Directive 2004/108/EC of the European Parliament and of the Council of 15 December 2004 on Electromagnetic Compatibility (EMC Directive).