PRODUCT SUPPORT MANUAL Y1-03-0138 Rev. H RCL-100D™ Remote Control Searchlight Master Controller Point Pad ACR Electronics, Inc. 5757 Ravenswood Road Fort Lauderdale, Fl 33312 +1(954) 981-3333 · Fax +1 (954) 983-5087 www.acrelectronics.com Email: Info@acrelectronics.
RCL-100D TABLE OF CONTENTS SECTION 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.
RCL-100D, 12/24V REMOTE CONTROL SEARCHLIGHT SYSTEM FIGURE 1: REMOTE CONTROL SEARCHLIGHT SYSTEM 1.0 FORWARD Congratulations and thank you for purchasing the ACR RCL-100D Searchlight. The combination of computer aided design, high quality raw materials, and quality-controlled manufacturing produce a superior product. The Test Facility at ACR can reproduce some of the harshest environmental conditions known to man. This assures that the products we produce can stand up to the tough marine environment.
2.0 GENERAL The RCL-100D was specially designed for mariners who require a high intensity remote controlled searchlight that can stand up to the tough marine environment. The RCL-100D Searchlight System contains a narrow beam searchlight that produces 200,000 peak candle power by combining two 55W halogen lamps with our unique optical quality parabolic reflectors.
.0 URP-102 POINT PAD™ Case Options The URP-102 Point Pad™ is supplied as a surface mount unit (see Figure4). A flush mount option is provided (see Figure 5). To switch mounting options, unscrew the six (6) screws on the unit’s back plate and remove the front cover. Fit the Point Pad™ with the flush mount cover, replace the back plate, and screw the unit back together. Mounting Both the surface mount and flush mount options require access to the backside of the mounting location.
URC-102 Master Controller Unit URC-102 Master Controller Unit RG-59 Coaxial Cable Fuse RG-59 Coaxial Cable Fuse URP-102 Point Pad Power Source “T” Conn. or Splitter Power Source RG-59 Coaxial Cable URP-102 Point Pad RG-59 Coaxial Cable URP-102 Point Pad Single Point Padä Multiple Point Padsä FIGURE 2: POINT PAD™ CONNECTION BLOCK DIAGRAM 4 Y1-03-0138 Rev.
URP-102 Point Pad Functions · · · · · · · Press the ON/OFF button to turn the lights ON or OFF. Press the SPEED button to toggle between High and Low rotation speeds. Press the Right or Left Arrows to rotate the Searchlight in that direction. Press the Up or Down Arrows to raise or lower the Searchlight-beam. To activate the XRCiZ feature, press and hold the ON/OFF button for greater than 5 seconds. The Green LED indicates XRCiZ feature is enabled.
6 FIGURE 4: URP-102 POINT PAD™ SURFACE MOUNT CASE Y1-03-0138 Rev.
7 FIGURE 5: URP-102 POINT PAD™ FLUSH MOUNT CASE Y1-03-0138 Rev.
8 FIGURE 6: URP-102 POINT PAD™ Surface Mount Case with gasket and Flush Mount Case with gasket Y1-03-0138 Rev.
6.0 URC-102 MASTER CONTROLLER Mounting The Master Controller can be mounted in any position near the Searchlight that is protected from the weather. Check in advance that the coax cable from the Point Pad™ and the wiring harness from the Searchlight can be routed to this location. Mount the Master controller with the wires and coax facing down. Use an appropriate fastener for your mounting location. Use a sealant in fastener holes to prevent moisture intrusion.
Wiring to Power Supply The power source must be a fused 12 VDC, 10-amp supply or 24 VDC, 5-amp supply. Following the wiring scheme in Table 1, use the supplied butt connectors to connect the Master controller to the Power Source. Refer to Table 2 for proper wire size for connection of the input power lines. NOTE: As per the wiring scheme, the ORANGE wire is connected to the Positive terminal and the BLUE wire is connected to the Negative terminal of the power source.
NOTE: The Searchlight should not be covered while the XRCiZ feature is enabled. The URC-102 Master Controller provides optimum voltage to ensure the brightest Searchlight performance and long bulb life. Also to extend lamp life, the Master Controller has a timed lamp power up feature. The Searchlight lamps reach full intensity within 2 seconds. The URC-102 Master Controller has a Searchlight motor timeout feature.
.34 [8.6] 2.80 [71.1] 4.50 [114.3] 3.63 [92.2] 3.64 [92.5] 1.15 [29.2] Figure 8: URC-102 MASTER CONTROLLER 12 Y1-03-0138 Rev.
7.0 RCL-100D SPECIFICATIONS (with URC-102 Controller) Specifications 12V UNIT 24V UNIT Mirror Diameter 4" x 2-3/4" Same Rated Voltage (Volt) 12 to 16 VDC 24 to 31 VDC Rated Current (A) 10 5 Applicable Lamp 55W Halogen 55W Halogen Lamp x 2 Lamp x 2 (Base-G6.35) (Base-G6.
ACR/RCL-100D ITEM NO.
8.0 BULB REPLACEMENT Two 55W, quartz-halogen bulbs are provided with your RCL-100D. If they should need replacement, they must be ordered through ACR Electronics, by P/N A1-14-0080-1 (12V units) or A1-14-0080-2 (24V units). To replace the lamps: 1. Disconnect unit from power source and allow bulbs to cool. 2. Remove two screws holding the front flange and glass in place. 3. To remove the old lamp bulbs, grasp base of the lamp and pull straight out.
PRODUCT NO. 1931.
Adapter Plate, Flush mount Adapter Plate, Surface mount Instruction Sheet, Point Pad™ Mounting Templates 1 1 1 1 A1-18-1871 A1-18-1892 Y1-06-0179 Y1-03-0138-1 PRODUCT NO. 1929.1 - Wiring Kit RCL-50 / 100 Series Searchlights Includes: Description Connector, “F” Cable, Coaxial Quantity 2 15' ACR Part Number A1-03-0220 A2-07-0002-6 PRODUCT NO. 9282.
PRODUCT NO. 9283.