Specifications

Y1-03-0138 Rev. H
10
Wiring to Power Supply
The power source must be a fused 12 VDC, 10-amp supply or 24 VDC, 5-amp supply.
Following the wiring scheme in Table 1, use the supplied butt connectors to connect the Master
controller to the Power Source. Refer to Table 2 for proper wire size for connection of the
input power lines.
NOTE: As per the wiring scheme, the ORANGE wire is connected to the Positive terminal
and the BLUE wire is connected to the Negative terminal of the power source.
NOTE: Observe polarities when attaching wires!
Maximum Cable Length
Wire Size 12v System 24v System
#8 AWG 25 ft. 100 ft.
#10 AWG 15 ft. 60 ft.
#12 AWG 10 ft. 40 ft.
Table 2
Function
The URC-102 Master Controller is designed to perform up to six different duties on
searchlights, winches, and other electrical devices. The Master Controller provides optimum
voltage to ensure brightest performance and long lamp life, regardless of boat system voltage
fluctuations. The Master Controller is compatible with devices requiring 12 VDC or 24 VDC
operation.
The URC-102 Master Controller has the unique XRCiZ feature. The XRCiZ feature routinely
operates all moving parts in the Searchlight to keep the motors and drive mechanism freely
running. Once activated, and every 30 days thereafter, the XRCiZ feature wakes up and
operates the Searchlight. The Searchlight will rotate 360° in both directions and the parabolic
reflectors will move to the full up and down positions. This feature keeps the Searchlight in
peak working order when not in service for long periods of time.
To activate the XRCiZ feature, press and hold the Point Pad™ ON/OFF button for greater than
5 seconds. The Green LED on the URC-102 Point Pad™ indicates that the XRCiZ feature is
enabled. While enabled, The XRCiZ feature can be started outside of its 30-day cycle by
pressing and holding the Speed button on the Point Pad™ for greater than 5 seconds.
While the XRCiZ feature is operating the Searchlight, pressing any Point Pad™ button will
stop the current cycle and leave the Searchlight to follow any additional commands.
To deactivate the XRCiZ feature, press and hold the Point Pad™ ON/OFF button for greater
than 5 seconds. The Red LED on the URC-102 Point Pad™ indicates that the XRCiZ feature is
disabled.
NOTE: LED feedback is not available when using RCL-100 or URC-101 Point Pads™.