4. APPENDIX
4.1. Approved Replacement Fuses
The Adams Rite Power Supply has two user serviceable fuses F1 and F2. These fuses are described
below:
F1 4 A/250V 5X20MM
226.5I8 SLOW-BLOW
Fuse F1 is in line with the transformer output (28VDC)
Little Fuse P/N: 213004. MXP
Adams Rite Mfg P/N: 29-0667
F2 3.15A/250V 5X20MM
202 I
2
t SLOW-BLOW
Fuse F2 is in line with the transformer input (120VAC/230VAC)
Little Fuse P/N: 2133.15.MXP
Adams Rite Mfg P/N: 29-0668
BBK-LR FUSES
BBK
-LR BATTERY BACKUP CHARGER FUSE IS THE SAME AS F1 (ABOVE)
FUSE REPLACEMENT MUST BE THE SAME RATING
Fuse F3 is not user serviceable. If replacement is needed, return to the factory.
This fuse will blow if fuse F1 is replaced with a fuse of higher value than recommended.
The average input current for the Adams Rite Power Supply is:
• 115 VAC 0.70 Amp
• 230 VAC 0.40 Amp.
**Caution**
INSTALLING A FUSE THAT EXCEEDS THE RATING OF THE ORIGINAL FUSE WILL BLOW F3,
AN INTERNAL FUSE AND VOID THE WARRANTY.THE ADAMS RITE POWER SUPPLY CAN NO
LONGER BE USED AND MUST BE SENT BACK TO THE FACTORY FOR REPLACEMENT
.