Installation Instructions

ADAMS RITE MANUFACTURING CO.
ADAMS RITE POWER SUPPL
ADAMS RITE POWER SUPPL
Y
Y
P
P
ART NUMBER PS-LR
ART NUMBER PS-LR
260 Sant
260 Sant
a Fe S
a Fe S
treet, Pomona, CA
treet, Pomona, CA
91767•800.872.3267•Fax 800.232.7329
91767•800.872.3267•Fax 800.232.7329
Need more information? Visit our website at:
www
www
.adamsrite.com
.adamsrite.com
Page 8 of 10
Rev Date: 10/2/07
80-0180-247 REV (G)
2. DESCRIPTIONS, PART NUMBERS, AND MEASUREMENTS
2.1. DESCRIPTIONS AND PAR
T NUMBERS
Two Wire Driver Board P/N# 31-0117-IP
Solenoid P/N# 31-0833-IP
Microswitch ( found on Solenoid ) P/N# 31-0101
PS-LR Board P/N# 29-0623
Battery Backup System Kit P/N# BBK-LR
Fuses for PS-LR Board (Can be purchased from Fuses Unlimited Ph # 1-800-255-1919)
F1 - 4 Amps* P/N# 0213004.MXP
F2 - 3.15 Amps* P/N# 02133.15P
F3 - 7 Amps* (unserviceable) P/N# 0230007.HXP
*All Slo Blo
2.2. SOLENOID
VALUE READINGS
Black/White Wires: Approximately 44 OHMS* / 28.5VDC* when powered
Black/Red Wires: 2 OHMS* / .6VDC* when powered
Microswitch: Blue wires set on Normally Closed**
* Can be measured from Two Wire Driver Board. Solenoid wires do not need to be
removed from board.
** If Microswitch is Open when no power applied, terminals may be set Normally
Open, Terminal Connectors are loose or Microswitch is failing and need replacing.
2.3. PS-LR
VALUE READINGS
OUT 1 & OUT 2 when IN1 / IN2 are open 1.6VDC
OUT 1 & OUT 2 when IN1 / IN2 are closed approximately 30VDC
2.4. LED CONFIGURA
TION
Power to PS-LR Board* Main Power (Red LED) Output Power (Green LED) ON.
* If OUT1 and/or OUT2 (green LED) are on and IN1 and IN2 are OPEN, Replace Board.
2.5. SW1 DIP SWIT
CH SETTINGS
Single Input # 1 On (controls one/pair opening)
Operation: Either Input retracts Exit Device # 1 immediately followed by Exit Device # 2.
Either IN1 / IN2 (green LED) will activate OUT1 (green LED) then OUT2 (green LED)
Dual Input # 1 Off (controls two separate openings)
Operation: IN1 retracts Exit Device # 1, IN2 retracts Exit Device # 2
IN1 (green LED) will activate OUT1 (green LED). IN2 (green LED) will activate OUT2 (green LED)
Refer to 1.3. Step 3 for Set Hold Open Times settings.