PDU DC supply (18-56 VDC with 5A fuse/breaker).
5. Re-connect to original configuration and return to service. PDU should illuminate a green
LED for each active TMA if there are no faults in the system.
6. Check with operators for improved performance.
4.2 Troubleshooting Hints
If voltage is outside of the normal range, trace it back towards the fault.
If no resistance or low resistance, check protector, feedline, jumpers and TMA.
If high resistance, check to see if TMA is installed or for a discontinuity up to the TMA.
Normal in-band RL should be greater than 14dB. If less than 14dB, check protector,
feedline, jumpers and antenna.
Mark receive and transmit bands to verify correct filtering.
Check distance to fault to identify any anomalies on the feedline.