User`s guide

Configuring the Controller
Adept SmartController User’s Guide, Rev. K 37
4. When the install is complete, click Finish.
5. After closing the Adept ACE Setup wizard, click Exit on the CD-ROM menu and
proceed to the Start-up Procedure.
NOTE: You will have to restart the PC after installing the Adept ACE
software
3.4 Configuring the Controller
The SmartController is shipped with the factory configuration described in this section.
See Figure 3-1 on page 31 for the location of DIP switch SW1. If you need to make changes
to this configuration, set DIP switch SW1 as described here.
Factory Default Settings
Refer to row #5 in Table 3-3 on page 37 for the factory default settings for DIP switch SW1.
With this default DIP switch setting, the system will read the configuration data from the
CompactFlash. This allows you to set all the configuration options in software without
changing the physical DIP switches.
DIP-Switch Settings
The following table shows the options for DIP switch SW1 on the SmartController.
Table 3-3. SW1 Settings
Row # SW1-1 SW1-2 SW1-3 SW1-4 Interpretation
1 ON ON ON ON No auto boot, all other settings per CompactFlash
2 OFF ON ON ON No auto boot, user interface via serial port
3ONONOFFON
No auto boot, user interface via Ethernet Adept ACE
(use IP address in CompactFlash)
4 OFF ON OFF ON
No auto boot, user interface via Ethernet Adept ACE
(use default IP address)
5 OFF OFF OFF OFF Operation per CompactFlash and NVRAM settings
OFF
ON
SW1
1 2 3 4