User`s guide

Connecting Customer-Supplied Safety and Power-Control Equipment
Adept SmartController User’s Guide, Rev. K 43
NOTE: The system was evaluated by Underwriters Laboratory with an
Adept Front Panel. If you provide a substitute Front Panel, this could
violate UL compliance.
Table 3-8. Contacts Provided by the XFP Connector
Pin
Pairs
Description
Requirements for
User-Supplied Front Panel
Voltage-Free Contacts Provided by Customer
1, 9
Front Panel E-Stop CH 1 User must supply N/C
contacts
2, 10
Front Panel E-Stop CH 2 User must supply N/C
contacts
3, 11
Remote Manual/Automatic switch CH 1. Manual =
Open Automatic = Closed
Optional - jumper closed for
Auto Mode-only operation
4, 12
Remote Manual/Automatic switch CH 2. Manual =
Open Automatic = Closed
Optional - jumper closed for
Auto Mode-only operation
6, 14
Remote High Power on/off momentary push-button User must supply
momentary push-button to
enable High Power to system
Nonvoltage-Free Contacts
5, 13
a
a
Users must exercise caution to avoid inadvertently connecting 24 V signals to these pins,
because this will damage the electronics.
Adept Supplied 5 VDC and GND for High Power
On/Off Switch Lamp
User must supply lamp, or
use 1 W, 47 ohm resistor -
system will not operate if not
present
7, 15
a
SmartController system 5 V power on LED, 5 V,
20 mA
Optional - indicator only
8 No connection
See Figure 3-5 on page 46 for a schematic diagram of the Adept Front Panel.
Pin 1
Pin 8
Pin 9
Pin 15
XFP