User`s guide

Chapter 3 - SmartController Operation
46 Adept SmartController User’s Guide, Rev. K
Figure 3-5. Front Panel Schematic
Emergency Stop Circuits
The SmartController provides connections for Emergency Stop (E-Stop) circuits on the
XUSR and XFP connectors. This gives the SmartController system the ability to duplicate
E-Stop functionality from a remote location using voltage-free contacts. See Figure 3-4 on
page 45.
The XUSR connector provides external two-channel E-Stop input on pins 1, 14 and 2, 15.
The XFP connector provides two-channel E-Stop input on pins 1 to 9 and 2 to 10.
NOTE: These pins must be shorted if not used. Both channels must open
independently if used. Although an Emergency Stop will occur, the
SmartController will flag an error state if one channel is jumpered closed
and the other channel is opened. It will also flag an error state if the
channels are shorted together.
User E-Stop Indication - Remote Sensing of E-Stop
A method has been provided to indicate the status of the ESTOP chain, inclusive of the
Front Panel Emergency Stop push-button, the pendant Emergency Stop push-button, and
the User Emergency Stop Contacts. Note: These contacts do not indicate the status of any
connections below the User E-Stop contacts. Thus, they will NOT indicate the status of the
Line E-Stop, MCP ENABLE, or the Muted Safety gate. If you have a specific need in this
area, contact Adept Customer Service for information on alternate indicating modes.
ESTOPSRC
24 VS
5 VD
D
SYSPWRLT 7
6
5
4
2
3
1
17
16
8
10
9
11
12
13
14
15
XFP
15PDSUBM
MANUALSRC1
HIPWRREQ
MANUALRLY2
MANUALRLY1
HIPWRLT
ESTOPFP2
ESTOPFP1
HPLT5V
NC
MANUALSRC2
"MANUAL/AUTO""System Power LED"
MANUALSRC1
SW1
MANUALRLY2
MANUALRLY1
MANUALSRC2
24 VS
"HIGH POWER ON/OFF"
SWL1
HIPWRREQ
HPLT5 V
HIPWRLT
D
ESTOPSRC
"EMERGENCY STOP"
SW2
ESTOPFP2
ESTOPFP1
5 VD
D
2-PIN_MINI
SYSPWRLT
Adept Front Panel Schematic