Owner manual

ASD8P-MT1 Specification Page 15 of 43
Test Description
Performance
criteria
Reference
standard
Radiated RF immunity
80~1000MHz, 3V/m,
80% AM with 1 KHz
sine
900 MHz, 3 V/m, 50%
pulse modulation at
200Hz
A
IEC 61000-4-3:
2008
Electrical fast transient
±1KV on AC mains ±0.
5KV on external I/O
B
IEC 61000-4-4:
2004
+Corr. 1: 2006
+Corr. 2: 2007
Surge immunity
±1KV differential ±2KV
common, AC mains
B
IEC 61000-4-5:
2005
Conducted RF immunity
150KHz~80 MHz, 3
Vrms, 80% AM with
1KHz sine
A
IEC 61000-4-6:
2008
Power frequency
magnetic field
50Hz, 1A/m (r. m. s. ) A
IEC 61000-4-6:
2008
Notes:
1) Performance criterion A = The device shall continue to operate as intended, i. e. ,
normal unit operation with no degradation of performance.
2) Performance criterion B = The device shall continue to operate as intended after
completion of test, however, during the test, some degradation of performance is
allowed as long as there is no data loss operator intervention to restore device function.
3) Performance criterion C = Temporary loss of function is allowed. Operator
intervention is acceptable to restore device function.
4) Contact electrostatic discharge is applied to drive enclosure.
Weight
13g Max. LGT-xxxB1P
Dimension
Form factor M. 2 2280: 80. 0 mm x 22. 0 mm x 3. 8 mm (L x W x H) LGT-xxxB1P