User guide

System Management 35
PXIS-2719A
Fan Speed
Auto/Full status of the PXIS-2719A is shown here, Auto is dis-
played when the cooling fans are set to auto mode and Full
when the fans are set to run full speed. Selection of Auto or
Full values and clicking Set directly changes cooling fan mode.
Alarm Threshold
Active alarm threshold settings are shown, including DC volt-
age, temperature, and fan speeds. The updated threshold set-
ting can also be set here, by entering the desired value and
clicking Set Threshold Settings.
3.3.2 Chassis Status
DC Voltage
The monitored 5V AUX, 3.3V, 5V, 12V, and -12V power rail
readings are shown here. The status shows as normal when
the readings are within the threshold range, and abnormal
when the readings exceed the threshold range.
Chassis Temperature
Eight temperature sensors on the top of the backplane, T1 to
T8 from left to right, provide readings, with status showing nor-
mal when the readings are within the threshold value (70°C in
the figure), and abnormal when the readings exceed the
threshold value.
Fan Speed
Monitored readings of the three cooling fans appear here. Sta-
tus shows as normal when readings exceed threshold value
(800 RPM in the figure), and abnormal when the readings fall
below the threshold value.