7
of the leak as a direct distance from the closer sensor. The correlator also may
be used to measure the actual velocity of sound in the pipe under
investigation, ensuring the greatest accuracy in locating the leak.
Note: This discussion assumes the correlator is connected directly to
both sensors. Since this is often impractical, the connections typically
are made using radio links with negligible delays. However, the
principle remains the same.