2.2 Installation Precautions
To keep the EKI-6311GN well while you are installing it, please read and follow these installation
precautions.
1. Users MUST use a proper and well-installed surge arrestor with the EKI-6311GN; otherwise, a
random lightening could easily cause fatal damage to EKI-6311GN.
EMD (Lightning) DAMAGE IS NOT COVERED UNDER WARRNTY.
2. Users MUST use the “Power cord & PoE Injector” shipped in the box with the EKI-6311GN.
Use of other options will cause damage to the EKI-6311GN.
3. Users MUST power off the EKI-6311GN first before connecting the external antenna to it. Do
not switch from built-in antenna to the external antenna from WEB management without
physically attaching the external antenna onto the EKI-6311GN; otherwise, damage might be
caused to the EKI-6311GN itself.
2.3 Hardware Installation
Connect up
1. The bottom of the EKI-6311GN is a movable cover. Grab the cover and pull it back harder to
take it out as the figure shown below.
Figure 2 Move the Cover
2. Plug a standard Ethernet cable into the RJ45 port.