CHARGING PHASES
The concept of the charging process is explained based on a 12 V battery.
Diagnosis
Diagnostic function which automatically checks the battery status and recognises the
voltage.
Voltage Function
0 V to 1.5 V “Error” LED (9) lit. Battery defective.
1.5 V to 12 V Charging starts.
12 V to 13 V Maintenance charging starts.
14.6 V Battery fully charged. “Full” LED (10) lit.
>15 V “Error” LED (9) lit.
Step 1: Condition check
The charger checks the battery condition and calculates the required
charging parameters.
Step 2: Desulphation (rescue)
The charger can rescue most drained batteries with voltages up to a minimum of
1.5 ±0.5 V.
The safety switch does not allow the charger to start charging if the voltage is
below 1.5 ± 0.5 V.