User manual

AB
min. 20
10
20
A
4.
Use at least 2 screws to fix the oven
on both sides (Detail A).
WARNING!
When installing next to a wood-
fuelled boiler, a heatproof and
heat-insulating plate must be
mounted at the height of the ap-
pliance and at least 30 cm deep.
12.2 Electrical connection
Use a power cable of H05VV-F or higher.
Connect the appliance to a socket sup-
ply line. If there is no socket supply line,
the electrical installation must have an
isolation device which lets you discon-
nect the appliance from the power sup-
ply. The isolation device must have a
contact opening width of minimum 3
mm (in reference to NIN SEV 1000). The
customer must have a socket for the
electrical connection that is accessible
and outside the coordination room. The
length of the connection cable must be
approximately 120 cm with lines connec-
ted directly to the power supply.
L2
L3
400V
L1PE
400V 3~
L2
400V
L1PE
400V 2~
123
45
123
45
Only a qualified person can con-
nect the appliance to the elec-
tricity supply.
1.
Do the electrical connections as in
the connection illustration.
Connection diagram 400V
Phase definitions: L1, L2, L3 (or R, S,
T).
2.
Secure the cable grip.
WARNING!
If service is required always dis-
connect the appliance from the
power supply.
28