User manual

BURNER Ø BYPASS 1/100 mm
Semi-rapid 32
Auxiliary 28
9.3 Other technical data
TOTAL POWER:
Gas original: G20 (2H) 20 mbar = 12 kW
Gas replacement: G30 (3+) 28-30 mbar = 858 g/h
G31 (3+) 37 mbar = 843 g/h
Electric supply: 220-240 V ~ 50/60 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp
cartridge fuse
Appliance category: II2H3+
Gas connection: R 1/2"
Appliance class: 3
WARNING!
This appliance does not
function with the existing
gas settings if installed in
Malta. Therefore, before
connecting the appliance it
is essential to change the
nozzles according to the
type of gas used according
to the table below.
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER kW MINIMUM POWER
kW
INJECTOR MARK
Triple Crown 4,0 1,4 146
Rapid 3,0 0,75 119
Semi-rapid 2,0 0,45 96
Auxiliary 1,0 0,33 70
www.aeg.com18