User manual

To override the function for only one
cooking time: activate the hob with .
comes on. Touch for 4 seconds.
Set the heat setting in 10 seconds. You
can operate the hob. When you
deactivate the hob with the function
operates again.
4.12 OffSound Control
(Deactivation and activation of
the sounds)
Deactivate the hob. Touch for 3
seconds. The display comes on and goes
out. Touch
for 3 seconds. or
comes on. Touch of the timer to
choose one of the following:
- the sounds are off
- the sounds are on
To confirm your selection wait until the
hob deactivates automatically.
When the function is set to you can
hear the sounds only when:
you touch
Minute Minder comes down
Count Down Timer comes down
you put something on the control
panel.
4.13 Power limitation
Originally the hob is at its highest
possible power level.
To decrease or increase the power
level:
1. Deactivate the hob.
2. Touch for 3 seconds. The display
comes on and goes off.
3. Touch for 3 seconds. or
comes on.
4. Touch
. P0 comes on.
5. Touch / of the Timer to set the
power level.
Power levels
Refer to “Technical information” chapter.
P0 — 7200 W
P1 — 1500 W
P2 — 2000 W
P3 — 2500 W
P4 — 3000 W
P5 — 3500 W
P6 — 4000 W
P7 — 4500 W
P8 — 5000 W
P9 — 6000 W
CAUTION!
Make sure that the selected
power fits to the house
installation fuses.
4.14 Power management
function
Cooking zones are grouped
according to the location and number
of the phases in the hob. See the
illustration.
Each phase has a maximum electricity
loading of 3700 W.
The function divides the power
between cooking zones connected to
the same phase.
The function activates when the total
electricity loading of the cooking
zones connected to a single phase
exceeds 3700 W.
The function decreases the power to
the other cooking zones connected to
the same phase.
The heat setting display of the
reduced zones changes between two
levels.
Power management function with
Power limitation function
When you set the Power limitation
function to 4.5 kW or less, power of the
hob is divided between all cooking
zones.
When you set the Power limitation
function to more than 4.5 kW, power of
ENGLISH