Cut Sheet

AC
34
AFC Cable Systems
®
800-757-6996 www.afcweb.com
Product Codes, Trade Sizes, Conductors, Packaging & Weights
Grounding Approx. Armor
Product Code Conductor Length (feet) Weight/1000 Minimum
Coil Reel Trade Size AWG Coil Reel Feet (lbs.) O.D. (inches)
120/208V
1504G42-00 1504G60-00 12-2 Solid (black,white) 12 solid 250' 1000' 220 0.489
1505G42-00 1505G60-00 12-3 Solid (black,red,white) 12 solid 250' 1000' 260 0.520
1506G42-00 1506G60-00 12-4 Solid (black,red, blue,white) 12 solid 250' 1000' 300 0.545
1507G42-00
1507G60-00
10-2 Solid (black,white) 10 solid 250'
290 0.500
1508G42-00
1508G60-00
10-3 Solid (black,red,white) 10 solid 250'
345 0.541
1509G42-00
1509G60-00
10-4 Solid (black,red, blue,white) 10 solid 250'
405 0.587
120/208V Specialty Colors
1504G42-04 1504G60-04 12-2 Solid (red, white) 12 solid 250' 1000' 220 0.489
1504G42-05 1504G60-05 12-2 Solid (blue, white) 12 solid 250' 1000' 220 0.489
480Y/277V
1504G42-01 1504G60-01 12-2 Solid (brown) 12 solid 250' 1000' 220 0.489
1504G42-02 1504G60-02 12-2 Solid (orange) 12 solid 250' 1000' 220 0.489
1504G42-03 1504G60-03 12-2 Solid (yellow) 12 solid 250' 1000' 220 0.489
1505G42-01 1505G60-01 12-3 Solid (brown, orange) 12 solid 250' 1000' 260 0.520
1506G42-01 1506G60-01 12-4 Solid (brown, orange, yellow) 12 solid 250' 1000' 300 0.545
HCF-90
®
Steel Healthcare Facilities Cable –
(120/208V &
480Y/277V
) Technical Specifications
NOTE: All dimensions and weights are subject to normal manufacturing tolerances.
Sizes 14 AWG, 8 AWG, & larger are available by special order and subject to lead time and minimum quantities.
Emergency circuits require special consideration in healthcare settings.
Review NEC® 517.30 (C)(3)(3) for guidance on the use of HCF cables on emergency circuits.
Galvanized Steel Armor
(Color-Coded Green)
Nylon Thermoplastic
THHN Insulation
Insulated
Bushing
Bare Aluminum
Bonding Strip
Insulated
Copper
Ground
Paper Wrap on
Each Conductor
Copper
Conductors
Specification Description
Specification HCF-90
®
ColorSpec
®
ID System
Armor Galvanized Interlocking Steel Strip
(green striped)
Conductors Solid Copper
Conductor THHN
Insulation
Conductor Moisture resistant
Insulation Fire Retardant Paper Wrap
Covering
Maximum
Temperature 90°C (dry)
Rating
Grounding 16 AWG integral Bond
Wire/Armor combination and
insulated green copper
250.118(B)
grounding conductor
250.118(1)
Neutral Conductor White 120/208V / Grey 480Y/277V
Maximum 600V
Voltage Rating
References & Ratings
UL 4, 83, 1479, 1581, 2556,
File Reference E7330
NEC
®
250.118(8), 300.22(C), 392,
320, 517.13, 518, 645
Federal Specification A-A-59544
(formerly J-C-30B)
Meets all applicable OSHA and HUD Requirements
Cable Tray Rated, install per NEC
®
UL Classified 1, 2, and 3 hour through (Fire) penetration product, R-14141
Environmental Air-Handling Space Installation per NEC
®
300.22(C)
Made in USA of US and/or imported materials
See page 45 for bond wire termination details.
CAT1106_CBL_AfcUS_Body_final 6/13/11 5:57 PM Page 34

Summary of content (1 pages)