Installation Guide

INSTALLATION INSTRUCTIONS
R
OUND
F
LUTED
6” & 8” S
NAP
-T
OGETHER
A
LUMINUM
C
OLUMN
AFCO Form AL03-R Rev. 7/2013
1. Measure the height of the opening where the column will be placed. Cut each col-
umn stave (piece)
1/4” longer than the opening. A circular saw with a metal cutting
blade is recommended for cutting the staves.
2.
To assemble the column, snap the interlocks of two staves together beginning at one
en
d and continuing along the length of the column. Add staves in the same manne
r
u
ntil column shaft is complete. Tap lightly with a rubber mallet if necessary.
For wrap-around-post installation: Follow above instructions but add final stave with
the partially assembled column in an upright position around the interior post.
3.
To secure the column, attach the column to the overhead beam or header with the
a
ppropriate fasteners and screws. Repeat this at the bottom of the column.
For whole capital and base: Before putting the column into position, place the assem-
bled column in the upright base. Slide the capital over the top of the column and all
th
e way down to rest on the base. Then, set the column with the capital and base into
place and plumb with a level. Secure the column.
Note: High performance tie down brackets are available at an additional charge.
4. To assemble and install the split capital and base, place the two pieces of the base
around the bottom of the secured column, flush with the floor and secure together
with PVC glue. Repeat this process with the capital at the top of the column. Be sure
the capital is flush with both the header and the base.
For whole capital and base: To secure the capital to the top of the secured column, pre-
drill holes and insert appropriate sized screws through the capital and the column wall.
Installer may elect to use an optional installation method by securing the capital in
place with construction adhesive. If needed, caulk between seams for a finished look.
Allow the base to rest on the floor. It is not recommended to secure the whole base to
the floor or to the column.
Note: For decorative capitals, see installation instructions provided with the decorative
capital.
Notes:
a. For best load-bearing performance, utilize AFCO load-bearing plates to spread the load over the entire perimeter of
the column. Load-bearing capacity is dependent on distributing the load evenly over the surfaces of the shaf
t.
b
. All column staves should be cut square and to the same length.
c. Installation should be on a smooth level surface.
d. 2nd story balconies should not be attached directly to the side of any column.
e. Columns should be installed according to standard construction practices and in compliance with applicable local,
state, and federal regulations.
SIZE CHART
C
OLUMN
S
IZE
S
TAVES
P
ER
C
OLUMN
M
AXIMUM
S
IZE
OF
E
XISTING
R
OUND
P
OST
M
AXIMUM
S
IZE
OF
E
XISTING
S
QUARE
P
OST
6 3 4
1/2 3 1/2
8 3 6
1/4” 4 1/2”
Round Fluted 6” & 8” Snap
Round Fluted 6” & 8” Snap
Round Fluted 6” & 8” Snap
-
-
-
Together Aluminum Column
Together Aluminum Column
Together Aluminum Column