User manual

QUICK REFERENCE
25
Modulation
AM (2100 series only)
Example: AM modulation. 100Hz modulating square wave. 1 Vpp,
1kHz Sine wave carrier. 70% modulation depth. Internal source
signal.
50
W
MAIN
1. Press the FUNC
key repeatedly to
select the Sine
wave.
FUNC
2. Press FREQ > 1 >
kHz.
FREQ
1
kHz/Vrms
3. Press AMPL > 1 >
Vpp.
AMPL
1
Hz/Vpp
4. Press AM.
AM
5. Press Shift >
INT/EXT > select
INT source.
Shift
+
INT/EXT
kHz/Vrms
6. Press Shift > Shape
repeatedly to select
the Square wave.
Shift
+
Shape
AM
7. Press Shift > Rate
> 1 > 0 > 0 > Hz.
Shift
+
Rate
FSK
1
0
0
Hz/Vpp