Instruction Manual

AAF Series LED Flushmount Fixture
Models: AAF121400L30D1xx, AAF162600L30D1xx
Page 1 of 1 8061003 R0
AAF162600L30
model shown
Safety Precautions
Read all safety precautions and installation instructions carefully
before installing or servicing this fixture. Failure to comply with
these instructions could result in potentially fatal electric shock
and/or property damage.
It is recommended that a qualified electrician perform all wiring. This
fixture must be wired in accordance with all national and local
electrical codes.
Do not handle any energized fixture or attempt to energize any
fixture with wet hands or while standing on a wet or damp surface or
in water.
This fixture is designed for use in a 110-120VAC, 60Hz fused circuit.
Make sure that the power source conforms to the requirements of the
fixture (see labels on fixture housing).
To reduce the risk of electrical shock, and to assure proper operation,
this fixture must be adequately grounded. To accomplish proper
grounding, there must be a separate ground wire (green) or bare metal
contact (metal conduit) between this fixture and the ground
connection of your main power supply panel. The green ground
screw location is clearly marked on the gem bar.
This fixture is intended to be used for general indoor lighting in dry
or damp locations only.
Assembly Instructions
1. Preparing for installation
A. Disconnect electrical power before installing or servicing any part
of this fixture.
B. Separate fixture (1) from mounting bracket (2), place fixture and
parts bag off to the side.
2. Wiring. All wiring must take place inside junction box.
Caution: Make sure power is off at fuse or circuit breaker box. Check power
wires for damage or scrapes. If power supply wires are within three inches of
driver use wire suitable for at least 90°C (194°F). Note: Most dwellings built
before 1985 have supply wire rated to 60°C. Consult a qualified electrician
before installing.
A. This unit will not operate properly unless connected to a “grounded”
electrical circuit. Electrical shock, overheating, low or no light
output, and shortened lamp life can result if proper grounding is not
done. Securely attach power source ground wire and fixture copper
ground wire to green ground screw on mounting bracket.
B. Using wire nuts (provided), connect white (common) supply wire to
white fixture lead. Connect black (hot) supply wire to black fixture lead. Do not mix wires. Pull on each
wire lead to make sure connections are secure. Make certain no bare wires are exposed outside of wire
connectors.
3. Fixture mounting
A. Align mounting bracket (2) to junction box (not supplied) with flat side facing toward ceiling and secure firmly with two #8-
32 x 1” screws (3). Install two wood screws (6) through outer slots into drywall anchor (5) for additional support.
B. Install pan (1) carefully to mounting bracket by aligning two side holes to the bracket and secure firmly with two screws (4).
4. Restore power at fuse or circuit breaker box.
Limited Factory Warranty
AFX Inc. hereby warranty that this fixture is free from defects in materials and workmanship when installed and used under normal operating
conditions for a period of 5 years from date of shipment from factory. This warranty covers all component parts and extends only to replacement of
defective fixture or components; it does not cover failure due to improper installation, misuse, mishandling or damage incurred in transit.