WARNING: THIS APPLIANCE MUST BE EARTHED.
THIS APPLIANCE IS DESIGNED FOR THE VOLTAGE STATED ON THE RATING PLATE, WHICH IS SITUATED
BEHIND THE LOWER LEFT HAND DOOR.
A 13 amp 230V ~ 50 Hz fused electrical supply is required adjacent to the appliance. External wiring to the unit must be
installed using a 3 core silicon - SIHF insulation cable, and in accordance with the current wiring regulations and any local
regulations which apply.
The method of connection to the mains electricity supply must facilitate complete electrical isolation of the appliance,
preferably by a fused double pole switch, having a contact separation of at least 3mm in both poles.
A 13A safety plug can be used, however, we do strongly recommend connection via a fused double pole switch for integrity
of the connection. If a 13A safety plug is used it must be of a high quality and must be to BS1363 - 3: 1995 (13A Plugs,
socket, outlets and adaptors).
NOTE: Switched spur outlet should only serve the appliance.
The isolator should not be positioned immediately above the cooker, but must be fitted within 2 metres of the appliance.
ELECTRICAL
5
Fig. 1A
EE-LMV MODEL
ABCDFGHKLMNR
116
TVWXYZ
mm
1487
889 851
679
1330
756
1125 3
698 484 816 52 790 873 55 699 662
* THIS HOLE IF REQUIRED FOR OVEN VENT PIPE IS TO BE CUT ON SITE IN
THE LEFT OR RIGHT HAND SIDE PANEL.