User Manual

SmartyCam
User Manual
Release 1.22 – firmware version 1.03.10
11
www.smartycam.com
Chapter 2 – Data sampled by SmartyCam stand alone/slave
As mentioned above, according to its working mode, SmartyCam provides different
information.
In Stand Alone mode, SmartyCam gets data from the integrated GPS and three-axial
accelerometer:
position;
GPS speed;
acceleration
lap time;
distance;
track mapping.
When connected to an AIM logger (EVO3 Pro/Pista, EVO4, MXL Strada/Pista/Pro05 or
MyChron4) or an ECU (via ECU bridge), SmartyCam can visualize in graphical overlay:
all info acquired in Stand Alone mode;
all info coming from the vehicle ECU;
all info sampled by the AIM logger (RPM, more speeds, LCU-ONE Lambda value,
engaged gear, temperatures, pressures, etc…).
When Connected to an RPM Bridge gets data from the integrated GPS and three-axial
accelerometer as well as engine RPM:
position;
GPS speed;
acceleration
lap time;
distance;
track mapping;
engine RPM.
PLEASE NOTE: for further useful information check:
www.aim-sportline.com website download area to know which ECUs are supported
by AIM loggers and their connection/communication protocols;
Race Studio Configuration user manual to understand how to configure AIM
loggers, AIM Bridges included;
each AIM logger user manual.